Fallenius, B. E. G., Sattari, A., Fransson, J. H. M. & Sandberg, M. (2013). Experimental study on the effect of pulsating inflow to an enclosure for improved mixing. International Journal of Heat and Fluid Flow, 44, 108-119
Åpne denne publikasjonen i ny fane eller vindu >>Experimental study on the effect of pulsating inflow to an enclosure for improved mixing
2013 (engelsk)Inngår i: International Journal of Heat and Fluid Flow, ISSN 0142-727X, E-ISSN 1879-2278, Vol. 44, s. 108-119Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Optimal control of inlet jet flows is of broad interest for enhanced mixing in ventilated rooms. The general approach in mechanical ventilation is forced convection by means of a constant flow rate supply. However, this type of ventilation may cause several problems such as draught and appearance of stagnation zones, which reduces the ventilation efficiency. A potential way to improve the ventilation quality is to apply a pulsating inflow, which has been hypothesised to reduce the stagnation zones due to enhanced mixing. The present study aims at testing this hypothesis, experimentally, in a small-scale two-dimensional water model using Particle Image Velocimetry with an in-house vortex detection program. We are able to show that for an increase in pulsation frequency or alternatively in the flow rate the stagnation zones are reduced in size and the distribution of vortices becomes more homogeneous over the considered domain. The number of vortices (all scales) increases by a factor of four and the swirl-strength by about 50% simply by turning on the inflow pulsation. Furthermore, the vortices are well balanced in terms of their rotational direction, which is validated by the symmetric Probability Density Functions of vortex circulation (Γ) around Γ= 0. There are two dominating vortex length scales in the flow, namely 0.6 and 0.8 inlet diameters and the spectrum of vortex diameters become broader by turning on the inflow pulsation. We conclude that the positive effect for enhanced mixing by increasing the flow rate can equally be accomplished by applying a pulsating inflow.

sted, utgiver, år, opplag, sider
Elsevier, 2013
Emneord
Pulsating flow, Room ventilation, Vortex statistics, Wall-jet instability, Kelvin-Helmholtz instability, Roll-up of vortices
HSV kategori
Identifikatorer
urn:nbn:se:oru:diva-82964 (URN)10.1016/j.ijheatfluidflow.2013.05.004 (DOI)000329594600009 ()2-s2.0-84888432075 (Scopus ID)
Forskningsfinansiär
Swedish Research CouncilGöran Gustafsson Foundation for promotion of scientific research at Uppala University and Royal Institute of TechnologyUniversity of Gävle
Merknad

QC 20140122

Tilgjengelig fra: 2014-01-22 Laget: 2020-06-11 Sist oppdatert: 2025-02-09bibliografisk kontrollert
Sattari, A., Fallenius, B., Fransson, J. H. M. & Sandberg, M. (2011). PIV Visualisation study in a two-dimensional room model with rapid time varying ventilation flow rates. In: Vojislav Novakovic, Sten Olaf Hanssen, Hans Martin Mathisen (Ed.), Roomvent 2011: proceedings. Paper presented at RoomVent 2011 - 12th International Conference on Air Distribution in Rooms, Trondheim, Norway, June 19-22, 2011. Tapir Academic Press
Åpne denne publikasjonen i ny fane eller vindu >>PIV Visualisation study in a two-dimensional room model with rapid time varying ventilation flow rates
2011 (engelsk)Inngår i: Roomvent 2011: proceedings / [ed] Vojislav Novakovic, Sten Olaf Hanssen, Hans Martin Mathisen, Tapir Academic Press , 2011Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

Optimal control of inlet jet flows is of wide applicative interest in order to enhance mixing and reduce stagnation in a ventilated room. The general approach in mechanical ventilation is to use a constant flow rate forced convection system providing the ventilation air. This type of ventilation may cause several problems such as draught, stagnation at certain occupied locations, and subsequently low ventilation efficiencies. An alternative to increase the ventilation quality that has been of interest in this study is to introduce flow variations, which is considered as a potential to reduce stagnation and increase efficiency of the ventilation. The study was conducted as a model experiment in a small-scale, two-dimensional (2-D) room model with dimensions 30200.9 cm3 with water as operating fluid. The size of the model made it possible to investigate the 2-D velocity vector field within the entire room using Particle Image Velocimetry (PIV) method and further consequent dynamical and statistical analyses have been done from the resulted PIV vector fields. The comparison between cases of constant flow rate and flow variations have been conducted for the cases of two set of base flow rates and for each one, the cases of constant flow rate and flow variations with frequencies of 0.3, 0.4 and 0.5 Hz, is considered. In this investigation we show that the calm region, with a large stagnation zone, without pulsating inflow condition becomes more active in the sense that the stagnation points are moved and that the small-scale structures are grown for increasing pulsation frequency.

sted, utgiver, år, opplag, sider
Tapir Academic Press, 2011
Emneord
PIV, room model, ventilation, varying flow rate
HSV kategori
Identifikatorer
urn:nbn:se:oru:diva-82967 (URN)978-82-519-2812-0 (ISBN)
Konferanse
RoomVent 2011 - 12th International Conference on Air Distribution in Rooms, Trondheim, Norway, June 19-22, 2011
Tilgjengelig fra: 2012-02-14 Laget: 2020-06-11 Sist oppdatert: 2025-02-10bibliografisk kontrollert
Organisasjoner
Identifikatorer
ORCID-id: ORCID iD iconorcid.org/0000-0002-3251-8328