New patient-controlled abdominal compression method in radiography: radiation dose and image quality
Örebro universitet, Institutionen för hälsovetenskaper. Department of Radiology.
Örebro universitet, Institutionen för medicinska vetenskaper. Region Örebro län. Department of Medical Physics.
Örebro universitet, Institutionen för hälsovetenskaper. Region Örebro län. University Health Care Research Center.ORCID-id: 0000-0001-7352-8234
Örebro universitet, Institutionen för medicinska vetenskaper. Department of Radiology.ORCID-id: 0000-0003-3253-8967
2018 (engelsk)Inngår i: Acta radiologica open, ISSN 2058-4601, Vol. 7, nr 5, s. 1-8, artikkel-id 2058460118772863Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Background: The radiation dose for patients can be reduced with many methods and one way is to use abdominal compression. In this study, the radiation dose and image quality for a new patient-controlled compression device were compared with conventional compression and compression in the prone position.

Purpose: To compare radiation dose and image quality of patient-controlled compression compared with conventional and prone compression in general radiography.

Material and Methods: An experimental design with quantitative approach. After obtaining the approval of the ethics committee, a consecutive sample of 48 patients was examined with the standard clinical urography protocol. The radiation doses were measured as dose-area product and analyzed with a paired t-test. The image quality was evaluated by visual grading analysis. Four radiologists evaluated each image individually by scoring nine criteria modified from the European quality criteria for diagnostic radiographic images.

Results: There was no significant difference in radiation dose or image quality between conventional and patient-controlled compression. Prone position resulted in both higher dose and inferior image quality.

Conclusion: Patient-controlled compression gave similar dose levels as conventional compression and lower than prone compression. Image quality was similar with both patient-controlled and conventional compression and was judged to be better than in the prone position.

sted, utgiver, år, opplag, sider
Sage Publications, 2018. Vol. 7, nr 5, s. 1-8, artikkel-id 2058460118772863
Emneord [en]
Compression, X-ray, image quality, radiation dose, radiography
HSV kategori
Identifikatorer
URN: urn:nbn:se:oru:diva-67002DOI: 10.1177/2058460118772863ISI: 000434653700001PubMedID: 29760949OAI: oai:DiVA.org:oru-67002DiVA, id: diva2:1209699
Merknad

Funding Agencies:

Research Committee of Region Örebro County  

Örebro University, Sweden 

Tilgjengelig fra: 2018-05-23 Laget: 2018-05-23 Sist oppdatert: 2018-07-24bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMed

Personposter BETA

Piippo-Huotari, OiliNorrman, EvaAnderzen-Carlsson, AgnetaGeijer, Håkan

Søk i DiVA

Av forfatter/redaktør
Piippo-Huotari, OiliNorrman, EvaAnderzen-Carlsson, AgnetaGeijer, Håkan
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 143 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf