To Örebro University

oru.seÖrebro universitets publikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Comparison of analytical methods and optimization ofreversed phase ion pair liquid chromatography UVdetectionfor the determination of EDTA in process andwastewater from paper and pulp manufacturing
Örebro universitet, Institutionen för naturvetenskap och teknik.
2019 (engelsk)Independent thesis Advanced level (degree of Master (One Year)), 10 poäng / 15 hpOppgave
Abstract [en]

Ethylenediaminetetraacetic acid (EDTA) is a chelating agent that is extensively used indifferent fields and industries. Multiple analytical techniques have previously been developedfor the determination of EDTA in water. This study was set up to compare different methodsas well as to optimize and implement a method for analytical determination of EDTA in processand wastewater from paper and pulp manufacturing. Three analytical methods whereinvestigated: 1) spectrophotometry, 2) gas chromatography – mass spectrometry (GC-MS) and3) reversed phase ion pair high performance liquid chromatography – UV detection (HPLCUV).Preliminary tests as well as literature studies indicated that HPLC was the best option toinvestigate further. The method was optimized by investigating complexing parameters as wellas mobile phase composition for the analysis of EDTA in waste and process water. The samplepreparation was performed by rapid complexation of EDTA with Fe(III) on a 60°C heatingblock for 30 minutes. The separation was achieved using a reversed phase column with a mobilephase containing 10 mM tetrabutylammonium bromide, 35 mM sodium formate, 6%acetonitrile at pH 3.3. The mobile phase was run isocratically with a flow rate of 1 mL/min andthe detection was carried out using a UV-detector operating at 260 nm. The method displayedgood accuracy and the limit of detection was 1.3 μg L-1. The method repeatability was testedon two effluent samples from pulp and paper manufacturing and was determined as 3.4%(n=20) and 1.7% (n=11). The optimized method was used to analyze a total of 40 process andwastewater samples from 12 different sampling locations at two paper and pulp factories, wherethe concentrations of EDTA ranged from 1.0 mg L -1 to 220 mg L -1.

sted, utgiver, år, opplag, sider
2019. , s. 26
HSV kategori
Identifikatorer
URN: urn:nbn:se:oru:diva-75687OAI: oai:DiVA.org:oru-75687DiVA, id: diva2:1341437
Fag / kurs
Chemistry
Veileder
Examiner
Tilgjengelig fra: 2019-08-08 Laget: 2019-08-08 Sist oppdatert: 2019-08-08bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric

urn-nbn
Totalt: 248 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf