Retrieved implants from irradiated sites in humans: A histologic/histomorhpometric investigation of oral and craniofacial implants
Örebro universitet, Institutionen för klinisk medicin.
Vise andre og tillknytning
2006 (engelsk)Inngår i: Clinical Implant Dentistry and Related Research, ISSN 1523-0899, E-ISSN 1708-8208, Vol. 8, nr 3, s. 142-150Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Purpose The aim of this report was to quantitatively and qualitatively evaluate the tissue response to bone-anchored implants retrieved from irradiated sites in patients.

Materials and Methods The material consists of 23 consecutively received Brånemark® implants (Nobel Biocare AB, Göteborg, Sweden) placed in pre- or postoperatively irradiated sites. Twenty-two of the 23 implants were suitable for histologic evaluation of undecalcified sections in the light microscope.

Results The oral implants with shorter time in situ demonstrated sparse bone to implant contact with mainly dense connective tissue in the interface. However, for implants with longer time in situ, high amounts of bone-implant contact and bone fill of threads were noted. The mean values of bone-implant contact and bone area within the thread were calculated to 40% (16–94) and 70% (13–96), respectively. The craniofacial implants, with the exception of two implants lined with a capsular formation, demonstrated mature and newly formed bone at the bone-implant interface. The mean value for bone-metal contact was calculated to 45 and 53% for two specimens. The mean value for bone area within the thread ranged from 65 to 88% for three specimens.

Conclusion The possibility to achieve bone anchorage of implants in irradiated tissue was supported by the findings in this study. However, due to limited material, conclusions with regard to radiation dose and bone tissue response to implants cannot be stated.

sted, utgiver, år, opplag, sider
Hamilton, Ont.: B.C. Decker , 2006. Vol. 8, nr 3, s. 142-150
HSV kategori
Forskningsprogram
medicin
Identifikatorer
URN: urn:nbn:se:oru:diva-4362DOI: 10.1111/j.1708-8208.2006.00010.xOAI: oai:DiVA.org:oru-4362DiVA, id: diva2:138661
Tilgjengelig fra: 2008-02-19 Laget: 2008-02-19 Sist oppdatert: 2017-12-14bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Personposter BETA

Johansson, Carina B.

Søk i DiVA

Av forfatter/redaktør
Johansson, Carina B.
Av organisasjonen
I samme tidsskrift
Clinical Implant Dentistry and Related Research

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 46 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf