oru.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Which surface properties enhance bone response to implants?: Comparison of oxidized magnesium, TiUnite, and Osseotite implant surfaces
Örebro universitet, Institutionen för klinisk medicin.
2006 (engelsk)Inngår i: International Journal of Prosthodontics, ISSN 0893-2174, E-ISSN 1139-9791, Vol. 19, nr 4, s. 319-328Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

PURPOSE: This study compared the speed and strength of osseointegration and osteoconductivity between an oxidized experimental magnesium (Mg) implant, an oxidized commercially available TiUnite implant, and a dual acid-etched surface Osseotite implant. The aim was to investigate which surface properties enhance bone response to implants, and thereby to test a biochemical bonding theory. MATERIALS AND METHODS: A total of 60 screw implants (20 of each design) were inserted through 1 cortex into the tibiae of 10 rabbits. Surface chemistry, oxide thickness, morphology, crystal structure, and surface roughness were evaluated. After healing times of 3 and 6 weeks, all bone implants were unscrewed with removal torque (RTQ) devices, and the bone specimens were subjected to histomorphometry. RESULTS: RTQ values for Mg, TiUnite, and Osseotite implants were 27.1, 21.3, and 15.4 Ncm, with new bone formation values of 29%, 18%, and 15%, respectively, at 3 weeks. At 6 weeks the RTQ values were 37.5, 36.4, and 21.5 Ncm, with new bone formation values of 39%, 31%, and 26%, respectively. Discussion: Mg implants demonstrated significantly greater RTQ values (P = .008 and P = .0001) and more new bone formation (P = .031 and P = .030) than Osseotite at 3 and 6 weeks, respectively. Mg implants also showed higher RTQ values at 3 weeks and new bone formation at 6 weeks than TiUnite, but neither were significant (P > .05). TiUnite showed significantly higher RTQ values than Osseotite at 6 weeks (P = .001), but was not significant at 3 weeks (P > .05). Osseointegration rate (deltaRTQ/deltaweeks) was significantly faster for Mg (P = .011) and TiUnite (P = .001) implants between 3 and 6 weeks of healing time, but was not significant for Osseotite. CONCLUSIONS: The results indicate that surface chemistry facilitated more rapid and stronger osseointegration of the Mg implants despite their minimal roughness compared to the moderately roughened TiUnite. This suggests potential advantages of Mg implants for reducing high implant failure rates in the early postimplantation stage and in compromised bone, making it possible to shorten bone healing time from surgery to functional loading, and enhancing the possibility of immediate/early loading.

sted, utgiver, år, opplag, sider
Lombard, Ill.: Quintessence Pub. Co. , 2006. Vol. 19, nr 4, s. 319-328
HSV kategori
Forskningsprogram
medicin
Identifikatorer
URN: urn:nbn:se:oru:diva-4373PubMedID: 16900812OAI: oai:DiVA.org:oru-4373DiVA, id: diva2:138672
Tilgjengelig fra: 2008-02-19 Laget: 2008-02-19 Sist oppdatert: 2017-12-14bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

PubMed

Personposter BETA

Johansson, Carina B

Søk i DiVA

Av forfatter/redaktør
Johansson, Carina B
Av organisasjonen
I samme tidsskrift
International Journal of Prosthodontics

Søk utenfor DiVA

GoogleGoogle Scholar

pubmed
urn-nbn

Altmetric

pubmed
urn-nbn
Totalt: 31 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf