oru.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Diagnosis of neonatal sepsis by broad-range 16S real-time polymerase chain reaction
Department of Pediatrics, Örebro University Hospital, Örebro, Sweden.
Clinical Research Centre, Örebro University Hospital, Örebro, Sweden.
Women’s and Children’s Health, Uppsala University, Uppsala, Sweden .
Örebro universitet, Hälsoakademin.
Vise andre og tillknytning
2012 (engelsk)Inngår i: Neonatology, ISSN 1661-7800, E-ISSN 1661-7819, Vol. 101, nr 4, s. 241-246Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Background: The standard diagnostic test (blood culture) for suspected neonatal sepsis has limitations in sensitivity and specificity, and 16S polymerase chain reaction (PCR) has been suggested as a new diagnostic tool for neonatal sepsis. Objectives: To develop and evaluate a new real-time PCR method for detection of bacterial DNA in blood samples collected from infants with suspected neonatal sepsis. Methods: Immediately after blood culture, a study sample of 0.5–1.0 ml whole blood was collected and used for a novel 16S real-time PCR assay. All positive samples were sequenced. Detailed case studies were performed in all cases with conflicting results, to verify if PCR could detect pathogens in culture negative sepsis. Results: 368 samples from 317 infants were included. When compared with blood culture, the assay yielded a sensitivity of 79%, a specificity of 90%, a positive predictive value of 59%, and a negative predictive value of 96%. Seven of the 31 samples with a positive PCR result and a negative blood culture had definite or suspected bacterial sepsis. In five samples, PCR (but not blood culture) could detect a pathogen that was present in a blood culture collected more than 24 h prior to the PCR sample. Conclusions: This study presents an evaluation of a new real-time PCR technique that can detect culture-positive sepsis, and suggests that PCR has the potential to detect bacteria in culture-negative samples even after the initiation of intravenous antibiotics.

sted, utgiver, år, opplag, sider
Basel, Switzerland: Karger , 2012. Vol. 101, nr 4, s. 241-246
Emneord [en]
Sepsis, Diagnosis, Polymerase chain reaction, Sensitivity and specificity
HSV kategori
Forskningsprogram
Pediatrik
Identifikatorer
URN: urn:nbn:se:oru:diva-20775DOI: 10.1159/000334655ISI: 000304894700003PubMedID: 22205207Scopus ID: 2-s2.0-84455202156OAI: oai:DiVA.org:oru-20775DiVA, id: diva2:475484
Tilgjengelig fra: 2012-01-10 Laget: 2012-01-10 Sist oppdatert: 2017-12-08bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMedScopus

Personposter BETA

Schollin, JensBjörkqvist, Maria

Søk i DiVA

Av forfatter/redaktør
Ohlin, AndreasBäckman, AndersSchollin, JensBjörkqvist, Maria
Av organisasjonen
I samme tidsskrift
Neonatology

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 78 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf