oru.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Magnetic Resonance Compatibility of a Transponder Aimed for Radiotherapy Positioning - A Phantom Study
Department of Surgical Sciences, Section of Radiology, Uppsala University, Uppsala, Sweden.
Department of Immunology, Genetics and Pathology, Section of Medical Radiation Sci-ence, Uppsala University, Uppsala, Sweden.
Örebro universitet, Institutionen för medicinska vetenskaper. Region Örebro län. Department of Oncology, Örebro University Hospital, Örebro, Sweden.
Örebro universitet, Institutionen för medicinska vetenskaper. Region Örebro län. Department of Oncology, Örebro University Hospital, Örebro, Sweden.
2017 (Engelska)Ingår i: Anticancer Research, ISSN 0250-7005, E-ISSN 1791-7530, Vol. 37, nr 9, s. 4993-4996Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Background/Aim: Electromagnetic Positioning Systems (EMP) is a new position-ing technique in four-dimensional radiotherapy. Patients with implanted transponders may be referred for magnetic resonance imaging (MRI) making it important to establish the MR safety.

Materials and Methods: Oranges were prepared with transponders and imaged on a 3T MR scanner with different sequences. Computed tomography (CT) was performed as comparison. MR artifacts were assessed. An estimation of the maximum transponder de-flection force and heating was made.

Results: The mean measured displacement of transponders was 0.1 mm (range=0.03-0.3 mm). Artifacts were observed adjacent to transponders using all sequences. The deflection force on the transponder in the gantry was less than 38 mN. No heating was observed.

Conclusion: The absence of any substantial movement, the weak measured deflection force and absence of observed heating speaks for the safe use of MR imaging with transponder 3T. Local artefacts makes evaluation impossible adjacent to transponders.

Ort, förlag, år, upplaga, sidor
International Institute of Anticancer Research, 2017. Vol. 37, nr 9, s. 4993-4996
Nyckelord [en]
Prostate cancer, electromagnetic positioning, four dimensional radiotherapy
Nationell ämneskategori
Cancer och onkologi
Identifikatorer
URN: urn:nbn:se:oru:diva-61934DOI: 10.21873/anticanres.11911ISI: 000412578200034PubMedID: 28870923Scopus ID: 2-s2.0-85029427695OAI: oai:DiVA.org:oru-61934DiVA, id: diva2:1152289
Tillgänglig från: 2017-10-24 Skapad: 2017-10-24 Senast uppdaterad: 2018-08-07Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Personposter BETA

Johansson, BengtLennernäs, Bo

Sök vidare i DiVA

Av författaren/redaktören
Johansson, BengtLennernäs, Bo
Av organisationen
Institutionen för medicinska vetenskaperRegion Örebro län
I samma tidskrift
Anticancer Research
Cancer och onkologi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 175 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf