Till Örebro universitet

oru.seÖrebro universitets publikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Comparison of analytical methods and optimization ofreversed phase ion pair liquid chromatography UVdetectionfor the determination of EDTA in process andwastewater from paper and pulp manufacturing
Örebro universitet, Institutionen för naturvetenskap och teknik.
2019 (Engelska)Självständigt arbete på avancerad nivå (magisterexamen), 10 poäng / 15 hpStudentuppsats (Examensarbete)
Abstract [en]

Ethylenediaminetetraacetic acid (EDTA) is a chelating agent that is extensively used indifferent fields and industries. Multiple analytical techniques have previously been developedfor the determination of EDTA in water. This study was set up to compare different methodsas well as to optimize and implement a method for analytical determination of EDTA in processand wastewater from paper and pulp manufacturing. Three analytical methods whereinvestigated: 1) spectrophotometry, 2) gas chromatography – mass spectrometry (GC-MS) and3) reversed phase ion pair high performance liquid chromatography – UV detection (HPLCUV).Preliminary tests as well as literature studies indicated that HPLC was the best option toinvestigate further. The method was optimized by investigating complexing parameters as wellas mobile phase composition for the analysis of EDTA in waste and process water. The samplepreparation was performed by rapid complexation of EDTA with Fe(III) on a 60°C heatingblock for 30 minutes. The separation was achieved using a reversed phase column with a mobilephase containing 10 mM tetrabutylammonium bromide, 35 mM sodium formate, 6%acetonitrile at pH 3.3. The mobile phase was run isocratically with a flow rate of 1 mL/min andthe detection was carried out using a UV-detector operating at 260 nm. The method displayedgood accuracy and the limit of detection was 1.3 μg L-1. The method repeatability was testedon two effluent samples from pulp and paper manufacturing and was determined as 3.4%(n=20) and 1.7% (n=11). The optimized method was used to analyze a total of 40 process andwastewater samples from 12 different sampling locations at two paper and pulp factories, wherethe concentrations of EDTA ranged from 1.0 mg L -1 to 220 mg L -1.

Ort, förlag, år, upplaga, sidor
2019. , s. 26
Nationell ämneskategori
Kemi
Identifikatorer
URN: urn:nbn:se:oru:diva-75687OAI: oai:DiVA.org:oru-75687DiVA, id: diva2:1341437
Ämne / kurs
Kemi
Handledare
Examinatorer
Tillgänglig från: 2019-08-08 Skapad: 2019-08-08 Senast uppdaterad: 2019-08-08Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Av organisationen
Institutionen för naturvetenskap och teknik
Kemi

Sök vidare utanför DiVA

GoogleGoogle Scholar

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 248 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf