New sensor system for drinking water quality
Örebro universitet, Institutionen för teknik.
Örebro universitet, Institutionen för teknik.
2004 (Engelska)Ingår i: Proceedings of the ISA/IEEE Sensors for industry conference, 2004, 2004, s. 30-34Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

A sensor system suitable for measuring qualitative changes In the chemical and the bacterial content in drinking water is presented. The sensor, an electronic tongue, is based on a voltammetric technique and is therefore robust, simple and sensitive to small changes of water quality in the measured sample. The sensor system is constructed so the liquid sample will flow through the sensing unit while measuring continuously. The sensor has a solid construction, does not contain any fragile parts and is independent of how it is positioned. This creates new approaches and the sensor can easily be mounted on a underwater vehicle for continuous inspection of drinking water reservoirs and continuously monitor the quality of the water as well as be mounted directly on a drinking water tap.

Ort, förlag, år, upplaga, sidor
2004. s. 30-34
Nationell ämneskategori
Teknik och teknologier
Forskningsämne
Industriell mätteknik
Identifikatorer
URN: urn:nbn:se:oru:diva-3218DOI: 10.1109/SFICON.2004.1287122ISBN: 0-7803-8143-2 (tryckt)OAI: oai:DiVA.org:oru-3218DiVA, id: diva2:137384
Konferens
ISA/IEEE Sensors for industry conference, 2004
Tillgänglig från: 2007-01-26 Skapad: 2007-01-26 Senast uppdaterad: 2017-10-18Bibliografiskt granskad
Ingår i avhandling
1. Electronic tongue for water quality assessment
Öppna denna publikation i ny flik eller fönster >>Electronic tongue for water quality assessment
2007 (Engelska)Doktorsavhandling, sammanläggning (Övrigt vetenskapligt)
Abstract [en]

This thesis describes the work on the development of a new electronic tongue for water quality assessment. The aim of this work is to build a complete system including a sensor and associated data analysis methods which is able to detect quality changes in drinking water and warn the user if the water is not suitable for drinking. Therefore, the main design issues were to build a portable, robust electronic tongue which provides a fast estimate of the water quality rather than identify the type of the contamination. In this sense, the system has a simple interface resembling traffic light signals. The system responds with green light for good water quality, red for bad quality and yellow if the result is uncertain.

The electronic tongue sensor is based on voltammetry, which gives a relatively simple and robust system. It is suitable for the considered applications, since it is able to measure small changes in the chemical and micro-organic content in water. These properties are very important for our goal to develop an electronic tongue for water quality assessment.

During the development process, the sensor system was modified in order to improve the system’s mobility and robustness. Moreover, the long-term stability and the extent of the sensor drift were evaluated for continuous use. The response time for the sensor is relatively short, but it generates large amounts of data. Therefore, there is a need for pre-processing and feature extraction methods to deal with the complexity of data. This is done with the help of multivariate analysis method. The quality assessment is done with different classification algorithms. We implemented fuzzy clustering and self-organizing maps.

In this thesis, two real applications are also considered, where the measurement is taking place in streaming water. In the first case, the electronic tongue could be placed directly at a water tap where random measurements occur. In the second application continuous measurements are performed and information about the sensor drift is used in the data analysis. The evaluation confirmed that the improved sensor system fulfills the requirements for on-line measurements of water quality.

Ort, förlag, år, upplaga, sidor
Örebro: Örebro universitetsbibliotek, 2007. s. 81
Serie
Örebro Studies in Technology, ISSN 1650-8580 ; 25
Nationell ämneskategori
Teknik och teknologier
Forskningsämne
Industriell mätteknik
Identifikatorer
urn:nbn:se:oru:diva-870 (URN)91-7668-524-1 (ISBN)
Disputation
2007-02-16, Hörsal T, Fakultetsgatan 1, Örebro, 13:00
Opponent
Handledare
Tillgänglig från: 2007-01-26 Skapad: 2007-01-25 Senast uppdaterad: 2017-10-18Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Person

Lindquist, MalinWide, Peter

Sök vidare i DiVA

Av författaren/redaktören
Lindquist, MalinWide, Peter
Av organisationen
Institutionen för teknik
Teknik och teknologier

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetricpoäng

doi
isbn
urn-nbn
Totalt: 329 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf