oru.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Facile preparation of glutathione-stabilized gold nanoclusters for selective determination of chromium (III) and chromium (VI) in environmental water samples
State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, China.
State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, China.
State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, China.ORCID-id: 0000-0002-5729-1908
State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, China.
Visa övriga samt affilieringar
2013 (Engelska)Ingår i: Analytica Chimica Acta, ISSN 0003-2670, E-ISSN 1873-4324, Vol. 770, s. 140-146Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

A novel method for selective determination of Cr(III) and Cr(VI) in environmental water samples was developed based on target-induced fluorescence quenching of glutathione-stabilized gold nanoclusters (GSH-Au NCs). Fluorescent GSH-Au NCs were synthesized by a one-step approach employing GSH as reducing/protecting reagent. It was found that Cr(III) and Cr(VI) showed pH-dependent fluorescence quenching capabilities for GSH-Au NCs, and thus selective determination of Cr(III) and Cr(VI) could be achieved at different pHs. Addition of EDTA was able to effectively eliminate the interferences from other metal ions, leading to a good selectivity for this method. Under optimized conditions, Cr(III) showed a linear range of 25-3800 μg L(-1) and a limit of detection (LOD) of 2.5 μg L(-1). The Cr(VI) ion demonstrated a linear range of 5-500 μg L(-1) and LOD of 0.5 μg L(-1). The run-to-run relative standard deviations (n=5) for Cr(III) and Cr(VI) were 3.9% and 2.8%, respectively. The recoveries of Cr(III) and Cr(VI) in environmental water samples were also satisfactory (76.3-116%). This method, with its simplicity, low cost, high selectivity and sensitivity, could be used as a promising tool for chromium analysis in environmental water samples.

Ort, förlag, år, upplaga, sidor
2013. Vol. 770, s. 140-146
Nyckelord [en]
Glutathione, Gold nanoclusters, Chromium, Environmental sample, Fluorescence quenching
Nationell ämneskategori
Miljövetenskap Analytisk kemi
Identifikatorer
URN: urn:nbn:se:oru:diva-38419DOI: 10.1016/j.aca.2013.01.042ISI: 000317252900017PubMedID: 23498696Scopus ID: 2-s2.0-84874969635OAI: oai:DiVA.org:oru-38419DiVA, id: diva2:765015
Anmärkning

Sponsors:

National Basic Research Program of China Grant no:s2009CB421605  2011CB936001 

National Natural Science Foundation of China  Grant no: 21107120  20977096 

Tillgänglig från: 2014-11-21 Skapad: 2014-11-07 Senast uppdaterad: 2018-05-22Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Personposter BETA

Wang, Thanh

Sök vidare i DiVA

Av författaren/redaktören
Wang, Thanh
I samma tidskrift
Analytica Chimica Acta
MiljövetenskapAnalytisk kemi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 516 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf