oru.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Verification of a Method for Measuring Parkinson’s Disease Related Temporal Irregularity in Spiral Drawings
School of Technology and Business Studies, Computer Engineering, Dalarna University, Falun, Sweden.
Örebro universitet, Handelshögskolan vid Örebro Universitet.ORCID-id: 0000-0002-2372-4226
School of Technology and Business Studies, Computer Engineering, Dalarna University, Falun, Sweden.
Department of Neuroscience, Neurology, Uppsala University, Uppsala, Sweden.
Vise andre og tillknytning
2017 (engelsk)Inngår i: Sensors, ISSN 1424-8220, E-ISSN 1424-8220, Vol. 17, nr 10, artikkel-id 2341Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Parkinson’s disease (PD) is a progressive movement disorder caused by the death of dopamine-producing cells in the midbrain. There is a need for frequent symptom assessment, since the treatment needs to be individualized as the disease progresses. The aim of this paper was to verify and further investigate the clinimetric properties of an entropy-based method for measuring PD-related upper limb temporal irregularities during spiral drawing tasks. More specifically, properties of a temporal irregularity score (TIS) for patients at different stages of PD, and medication time points were investigated. Nineteen PD patients and 22 healthy controls performed repeated spiral drawing tasks on a smartphone. Patients performed the tests before a single levodopa dose and at specific time intervals after the dose was given. Three movement disorder specialists rated videos of the patients based on the unified PD rating scale (UPDRS) and the Dyskinesia scale. Differences in mean TIS between the groups of patients and healthy subjects were assessed. Test-retest reliability of the TIS was measured. The ability of TIS to detect changes from baseline (before medication) to later time points was investigated. Correlations between TIS and clinical rating scores were assessed. The mean TIS was significantly different between healthy subjects and patients in advanced groups (p-value = 0.02). Test-retest reliability of TIS was good with Intra-class Correlation Coefficient of 0.81. When assessing changes in relation to treatment, TIS contained some information to capture changes from Off to On and wearing off effects. However, the correlations between TIS and clinical scores (UPDRS and Dyskinesia) were weak. TIS was able to differentiate spiral drawings drawn by patients in an advanced stage from those drawn by healthy subjects, and TIS had good test-retest reliability. TIS was somewhat responsive to single-dose levodopa treatment. Since TIS is an upper limb high-frequency-based measure, it cannot be detected during clinical assessment.

sted, utgiver, år, opplag, sider
Basel: MDPI AG , 2017. Vol. 17, nr 10, artikkel-id 2341
Emneord [en]
Parkinson’s disease; smartphone; spiral tests; temporal irregularity; timing variability; motor assessment; approximate entropy; complexity
HSV kategori
Forskningsprogram
Informatik
Identifikatorer
URN: urn:nbn:se:oru:diva-61534DOI: 10.3390/s17102341ISI: 000414931500183PubMedID: 29027941Scopus ID: 2-s2.0-85032855199OAI: oai:DiVA.org:oru-61534DiVA, id: diva2:1149171
Forskningsfinansiär
Knowledge FoundationVINNOVA
Merknad

Funding Agencies:

Cenvigo AB  

Sensidose AB  

Swedish ICT Acreo  

Uppsala University  

Sahlgrenska University  

Dalarna University 

Tilgjengelig fra: 2017-10-13 Laget: 2017-10-13 Sist oppdatert: 2018-09-12bibliografisk kontrollert

Open Access i DiVA

fulltext(497 kB)177 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 497 kBChecksum SHA-512
82ce83e6d3e31429c596b98d449a71ba4b28e4175a27fbfdd1bc70775f4a9ebdffe86ae5099781bffe833016ffae048c2dea8fbc262510fbd6836b7793aa61c4
Type fulltextMimetype application/pdf

Andre lenker

Forlagets fulltekstPubMedScopus

Personposter BETA

Memedi, Mevludin

Søk i DiVA

Av forfatter/redaktør
Memedi, Mevludin
Av organisasjonen
I samme tidsskrift
Sensors

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 177 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 596 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf