CT image metal artifacts in proton radiotherapy treatment planning: evaluation of two commercial correction algorithms
Örebro universitet, Institutionen för medicinska vetenskaper.
The Skandion Clinic, Uppsala, Sweden.
Department of Oncology, Faculty of Medicine and Health, Örebro University, Sweden.
Örebro universitet, Institutionen för medicinska vetenskaper. Region Örebro län. Unit of Biostatistics, Institute of Environmental Medicine, Karolinska Institutet, Stockholm, Sweden. (Clinical Epidemiology and Biostatistics)ORCID-id: 0000-0002-3552-9153
Vise andre og tillknytning
(engelsk)Manuskript (preprint) (Annet vitenskapelig)
HSV kategori
Identifikatorer
URN: urn:nbn:se:oru:diva-65012OAI: oai:DiVA.org:oru-65012DiVA, id: diva2:1182894
Tilgjengelig fra: 2018-02-15 Laget: 2018-02-15 Sist oppdatert: 2020-12-01bibliografisk kontrollert
Inngår i avhandling
1. Metal artifacts in computed tomography: impact of reduction methods on image quality and radiotherapy treatment planning
Åpne denne publikasjonen i ny fane eller vindu >>Metal artifacts in computed tomography: impact of reduction methods on image quality and radiotherapy treatment planning
2018 (engelsk)Doktoravhandling, med artikler (Annet vitenskapelig)
Abstract [en]

Degradation of image quality by metal artifacts is a common problem in computed tomography (CT) imaging, which can limit the diagnostic value of a CT examination and also introduce inaccuracies in radiotherapy (RT) treatment planning. In recent years, commercial metal artifact reduction (MAR) methods have been launched by several CT vendors. The overall aim of this thesis was to evaluate MAR methods in diagnostic imaging and RT treatment planning.

Evaluations of hip prosthesis phantom CT images showed that MAR algorithms in general improved image quality, based on both visual grading analysis and quantitative measures, while the application of virtual monoenergetic reconstructions insufficiently reduced metal artifacts. In some cases additional artifacts were introduced by the MAR algorithms. MAR algorithms were also evaluated in hip prosthesis phantom CT imaging used for proton therapy treatment planning, where improvements in dose calculation accuracy were observed.

Studies of Head & Neck (H&N) implant CT images in RT treatment planning were also performed. By visual grading of anatomy visualization with respect to target delineation in dental implant patient images, MAR algorithms were shown to significantly improve image quality. However, only minor effects of H&N implant artifacts on proton dose distributions were seen. The impact might be greater for more severe artifacts than those studied here, and thus further investigations of such cases are needed.

In conclusion, MAR algorithms have been shown to enhance image quality for diagnostic applications and to improve anatomy visualization in RT treatment planning. The MAR algorithms led to increased proton dose calculation accuracy in some cases, while in other situations only minor changes were seen.

sted, utgiver, år, opplag, sider
Örebro: Örebro University, 2018. s. 81
Serie
Örebro Studies in Medicine, ISSN 1652-4063 ; 172
Emneord
computed tomography, metal artifacts, image quality, visual grading analysis, radiotherapy, proton therapy, hip prosthesis, dental implants
HSV kategori
Identifikatorer
urn:nbn:se:oru:diva-63420 (URN)978-91-7529-228-1 (ISBN)
Disputas
2018-03-09, Örebro universitet, Campus USÖ, hörsal C3, Södra Grev Rosengatan 32, Örebro, 09:30 (svensk)
Opponent
Veileder
Tilgjengelig fra: 2017-12-19 Laget: 2017-12-19 Sist oppdatert: 2018-02-15bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Person

Andersson, Karin M.Cao, YangThunberg, Per

Søk i DiVA

Av forfatter/redaktør
Andersson, Karin M.Cao, YangThunberg, Per
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric

urn-nbn
Totalt: 800 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf