Compressive sensing in electrical impedance tomography for breathing monitoring
Department of Electronic and Electrical Engineering, University College London, London, United Kingdom.
Örebro universitet, Institutionen för naturvetenskap och teknik.ORCID-id: 0000-0003-2960-3094
Department of Physics and Electrical Engineering, Linnaeus University, Växjö, Sweden.
Department of Medical Physics and Biomedical Engineering, University College London, London, United Kingdom.
Vise andre og tillknytning
2019 (engelsk)Inngår i: Physiological Measurement, ISSN 0967-3334, E-ISSN 1361-6579, Vol. 40, nr 3, artikkel-id 034010Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Objective: Electrical impedance tomography (EIT) is a functional imaging technique in which cross-sectional images of structures are reconstructed based on boundary trans-impedance measurements. Continuous functional thorax monitoring using EIT has been extensively researched. Increasing the number of electrodes, number of planes and frame rate may improve clinical decision making. Thus, a limiting factor in high temporal resolution, 3D and fast EIT is the handling of the volume of raw impedance data produced for transmission and its subsequent storage. Owing to the periodicity (i.e. sparsity in frequency domain) of breathing and other physiological variations that may be reflected in EIT boundary measurements, data dimensionality may be reduced efficiently at the time of sampling using compressed sensing techniques. This way, a fewer number of samples may be taken.

Approach: Measurements using a 32-electrode, 48-frames-per-second EIT system from 30 neonates were post-processed to simulate random demodulation acquisition method on 2000 frames (each consisting of 544 measurements) for compression ratios (CRs) ranging from 2 to 100. Sparse reconstruction was performed by solving the basis pursuit problem using SPGL1 package. The global impedance data (i.e. sum of all 544 measurements in each frame) was used in the subsequent studies. The signal to noise ratio (SNR) for the entire frequency band (0 Hz–24 Hz) and three local frequency bands were analysed. A breath detection algorithm was applied to traces and the subsequent error-rates were calculated while considering the outcome of the algorithm applied to a down-sampled and linearly interpolated version of the traces as the baseline.

Main results: SNR degradation was generally proportional with CR. The mean degradation for 0 Hz–8 Hz (of interest for the target physiological variations) was below ~15 dB for all CRs. The error-rates in the outcome of the breath detection algorithm in the case of decompressed traces were lower than those associated with the corresponding down-sampled traces for CR  ⩾  25, corresponding to sub-Nyquist rate for breathing frequency. For instance, the mean error-rate associated with CR  =  50 was ~60% lower than that of the corresponding down-sampled traces.

Significance: To the best of our knowledge, no other study has evaluated the applicability of compressive sensing techniques on raw boundary impedance data in EIT. While further research should be directed at optimising the acquisition and decompression techniques for this application, this contribution serves as the baseline for future efforts.

sted, utgiver, år, opplag, sider
Institute of Physics Publishing (IOPP), 2019. Vol. 40, nr 3, artikkel-id 034010
Emneord [en]
Breath detection, compressive sensing, electrical impedance tomography
HSV kategori
Identifikatorer
URN: urn:nbn:se:oru:diva-73510DOI: 10.1088/1361-6579/ab0daaISI: 000463392300006PubMedID: 30844770Scopus ID: 2-s2.0-85064239164OAI: oai:DiVA.org:oru-73510DiVA, id: diva2:1302333
Forskningsfinansiär
EU, Horizon 2020, 668259Tilgjengelig fra: 2019-04-04 Laget: 2019-04-04 Sist oppdatert: 2023-12-08bibliografisk kontrollert

Open Access i DiVA

Compressive sensing in electrical impedance tomography for breathing monitoring(1220 kB)284 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 1220 kBChecksum SHA-512
60a197cdab5067fdfbed23d0b7ebe797d844b7eccd98a60e890d38e368c5d5f59cd72dec6e3b3b7496b1c3a01002021739ca1525ce9e32f4f9caae296b72a834
Type fulltextMimetype application/pdf

Andre lenker

Forlagets fulltekstPubMedScopus

Person

Khodadad, Davood

Søk i DiVA

Av forfatter/redaktør
Khodadad, Davood
Av organisasjonen
I samme tidsskrift
Physiological Measurement

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 284 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 425 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf