oru.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Outcome measurement instruments for erythema associated with incontinence-associated dermatitis: systematic review
Skin Integrity Research Group (SKINT), University Centre for Nursing and Midwifery, Department of Public Health and Primary Care, Ghent University, Ghent, Belgium.
Clinical Research Center for Hair and Skin Science, Department of Dermatology and Allergy, Charité - Universitätsmedizin Berlin, Germany.
Skin Integrity Research Group (SKINT), University Centre for Nursing and Midwifery, Department of Public Health and Primary Care, Ghent University, Ghent, Belgium; Clinical Research Center for Hair and Skin Science, Department of Dermatology and Allergy, Charité - Universitätsmedizin Berlin, Germany.
Skin Integrity Research Group (SKINT), University Centre for Nursing and Midwifery, Department of Public Health and Primary Care, Ghent University, Ghent, Belgium.
Visa övriga samt affilieringar
2019 (Engelska)Ingår i: Journal of Advanced Nursing, ISSN 0309-2402, E-ISSN 1365-2648Artikel, forskningsöversikt (Refereegranskat) Epub ahead of print
Abstract [en]

AIM: To: (1) examine which outcome measurement instruments for erythema associated with incontinence-associated dermatitis with supporting evidence about measurement properties are available; (2) evaluate the methodological quality of the studies and the quality of the measurement properties; and (3) identify eligible instruments to measure erythema in incontinence-associated dermatitis research.

DESIGN: Systematic review.

DATA SOURCES: MEDLINE, EMBASE, CINAHL and CENTRAL were systematically searched until July 2018 (update December 2018). Additional input was gathered from 151 incontinence-associated dermatitis experts. Cited and citing references of included studies were screened.

REVIEW METHODS: The COSMIN Risk of Bias checklist was applied to evaluate the methodological quality of the studies. Reported measurement properties were rated against criteria for good measurement properties.

RESULTS: Fourteen studies, describing 10 measurement instruments, were included. In five instruments, erythema was captured as a separate concept, two studies provided empirical evidence about the measurement properties. The most studied measurement properties were reliability (9 studies), measurement error (4 studies) and criterion validity (4 studies). In one study, internal consistency was examined.

CONCLUSION: No instrument measuring exclusively erythema associated with incontinence-associated dermatitis exists. There is no single composite incontinence-associated dermatitis measurement instrument that outperforms others. Development or adaption of an instrument to measure erythema associated with incontinence-associated dermatitis is one option to solve this challenge.

IMPACT: The evidence about measurement properties of instruments measuring erythema associated with incontinence-associated dermatitis has not been summarized to date. The lack of an instrument should trigger activities to measure this domain accurately in future clinical trials.

Ort, förlag, år, upplaga, sidor
Blackwell Publishing, 2019.
Nyckelord [en]
core outcome set, dermatology, erythema, incontinence-associated dermatitis, irritant contact dermatitis, literature review, measurement properties, nursing, outcome measurement instruments, systematic review
Nationell ämneskategori
Medicinsk laboratorie- och mätteknik
Identifikatorer
URN: urn:nbn:se:oru:diva-74702DOI: 10.1111/jan.14102ISI: 000479615200001PubMedID: 31197869OAI: oai:DiVA.org:oru-74702DiVA, id: diva2:1325678
Anmärkning

Funding Agency:

Ghent University Special Research Fund

Tillgänglig från: 2019-06-17 Skapad: 2019-06-17 Senast uppdaterad: 2019-11-14Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMed

Personposter BETA

Beeckman, Dimitri

Sök vidare i DiVA

Av författaren/redaktören
Beeckman, Dimitri
Av organisationen
Institutionen för hälsovetenskaper
I samma tidskrift
Journal of Advanced Nursing
Medicinsk laboratorie- och mätteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 101 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf