Till Örebro universitet

oru.seÖrebro universitets publikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Stable refraction and visual acuity in diabetic patients with variable glucose levels under routine care
Lund Univ, Malmö, Sweden.
Lund Univ, Malmö, Sweden.ORCID-id: 0000-0003-4273-0741
Lund Univ, Malmö, Sweden.
2011 (Engelska)Ingår i: Acta Ophthalmologica, ISSN 1755-375X, E-ISSN 1755-3768, Vol. 89, nr 2, s. 107-110Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

PURPOSE: To investigate how refraction and visual acuity may vary in patients with diabetes under routine care.

METHODS: Fifty-three eyes of 53 patients with various degrees of diabetic retinopathy were examined prospectively on four different occasions within a month. Refraction, best-corrected visual acuity (expressed as logMAR score) and blood glucose were measured on each occasion. Intraindividual variability was calculated as the range between the highest and lowest measurements. Associations between blood glucose levels and each of the other variables were tested by linear regression analysis for each patient.

RESULTS: Refraction was completely stable in 43 patients and changed only slightly in 10, in whom the mean intraindividual variability of the spherical equivalent was 0.4 dioptres. Visual acuity test results were also highly reproducible. Mean intraindividual variability in visual acuity was 0.08 logMAR. Mean haemoglobin A1c (HbA1c) was 7.3 ± 1.5% but individual blood glucose levels ranged from 2.8 to > 22.2 mmol/l. Intraindividual variability ranged from 0.5 to 18.1 mmol/l, with a median of 6.0 mmol/l for the entire group. There were no associations between refraction or visual acuity and blood glucose levels or inter- or intraindividual glucose variations.

CONCLUSION: Refraction and visual acuity test results were highly reproducible and stable in patients with reasonably well controlled diabetes but variable blood glucose levels under routine care.

Ort, förlag, år, upplaga, sidor
Wiley-Blackwell, 2011. Vol. 89, nr 2, s. 107-110
Nyckelord [en]
Blood glucose, diabetes, refraction, visual acuity
Nationell ämneskategori
Oftalmologi
Identifikatorer
URN: urn:nbn:se:oru:diva-82326DOI: 10.1111/j.1755-3768.2009.01664.xISI: 000287664700028PubMedID: 19843017Scopus ID: 2-s2.0-79952241022OAI: oai:DiVA.org:oru-82326DiVA, id: diva2:1434412
Tillgänglig från: 2020-06-03 Skapad: 2020-06-03 Senast uppdaterad: 2024-03-05Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Hellgren, Karl-Johan

Sök vidare i DiVA

Av författaren/redaktören
Hellgren, Karl-Johan
I samma tidskrift
Acta Ophthalmologica
Oftalmologi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 171 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf