PIV Visualisation study in a two-dimensional room model with rapid time varying ventilation flow rates
University of Gävle, Gävle, Sweden.ORCID-id: 0000-0003-2421-7792
The Royal Institute of Technology (KTH), Stockholm, Sweden.
The Royal Institute of Technology (KTH), Stockholm, Sweden.ORCID-id: 0000-0002-3251-8328
University of Gävle, Gävle, Sweden.
2011 (engelsk)Inngår i: Roomvent 2011: proceedings / [ed] Vojislav Novakovic, Sten Olaf Hanssen, Hans Martin Mathisen, Tapir Academic Press , 2011Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

Optimal control of inlet jet flows is of wide applicative interest in order to enhance mixing and reduce stagnation in a ventilated room. The general approach in mechanical ventilation is to use a constant flow rate forced convection system providing the ventilation air. This type of ventilation may cause several problems such as draught, stagnation at certain occupied locations, and subsequently low ventilation efficiencies. An alternative to increase the ventilation quality that has been of interest in this study is to introduce flow variations, which is considered as a potential to reduce stagnation and increase efficiency of the ventilation. The study was conducted as a model experiment in a small-scale, two-dimensional (2-D) room model with dimensions 30200.9 cm3 with water as operating fluid. The size of the model made it possible to investigate the 2-D velocity vector field within the entire room using Particle Image Velocimetry (PIV) method and further consequent dynamical and statistical analyses have been done from the resulted PIV vector fields. The comparison between cases of constant flow rate and flow variations have been conducted for the cases of two set of base flow rates and for each one, the cases of constant flow rate and flow variations with frequencies of 0.3, 0.4 and 0.5 Hz, is considered. In this investigation we show that the calm region, with a large stagnation zone, without pulsating inflow condition becomes more active in the sense that the stagnation points are moved and that the small-scale structures are grown for increasing pulsation frequency.

sted, utgiver, år, opplag, sider
Tapir Academic Press , 2011.
Emneord [en]
PIV, room model, ventilation, varying flow rate
HSV kategori
Identifikatorer
URN: urn:nbn:se:oru:diva-82967ISBN: 978-82-519-2812-0 (tryckt)OAI: oai:DiVA.org:oru-82967DiVA, id: diva2:1438696
Konferanse
RoomVent 2011 - 12th International Conference on Air Distribution in Rooms, Trondheim, Norway, June 19-22, 2011
Tilgjengelig fra: 2012-02-14 Laget: 2020-06-11 Sist oppdatert: 2020-12-01bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Person

Sattari, AmirFransson, Jens H. M.

Søk i DiVA

Av forfatter/redaktør
Sattari, AmirFransson, Jens H. M.

Søk utenfor DiVA

GoogleGoogle Scholar

isbn
urn-nbn

Altmetric

isbn
urn-nbn
Totalt: 166 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf