A sample of printed wiring boards, isolated from ground, has been charged tribo-electrically and the charge decay process has been studied with focus on the long-term charge decay behaviour. It was found that the time constant 1/e did not say much about the proceeding decay process. Instead a second-order approximation model for the measured decay curves has been suggested.