oru.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Protein adsorption to surface chemistry and crystal structure modification of titanium surfaces
Örebro universitet, Hälsoakademin.
Örebro universitet, Hälsoakademin.ORCID-id: 0000-0001-8304-2772
Visa övriga samt affilieringar
2010 (Engelska)Ingår i: Journal of oral & maxillofacial research, ISSN 2029-283X, Vol. 1, nr 3, s. e3-Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Objectives: To observe the early adsorption of extracellular matrix and blood plasma proteins to magnesium-incorporated titanium oxide surfaces, which has shown superior bone response in animal models.

Material and Methods: Commercially pure titanium discs were blasted with titanium dioxide (TiO2) particles (control), and for the test group, TiO2 blasted discs were further processed with a micro-arc oxidation method (test). Surface morphology was investigated by scanning electron microscopy, surface topography by optic interferometry, characterization by X-ray photoelectron spectroscopy (XPS), and by X-ray diffraction (XRD) analysis. The adsorption of 3 different proteins (fibronectin, albumin, and collagen type I) was investigated by an immunoblotting technique.

Results: The test surface showed a porous structure, whereas the control surface showed a typical TiO2 blasted structure. XPS data revealed magnesium-incorporation to the anodic oxide film of the surface. There was no difference in surface roughness between the control and test surfaces. For the protein adsorption test, the amount of albumin was significantly higher on the control surface whereas the amount of fibronectin was significantly higher on the test surface. Although there was no significant difference, the test surface had a tendency to adsorb more collagen type I.

Conclusions: The magnesium-incorporated anodized surface showed significantly higher fibronectin adsorption and lower albumin adsorption than the blasted surface. These results may be one of the reasons for the excellent bone response previously observed in animal studies.

Ort, förlag, år, upplaga, sidor
2010. Vol. 1, nr 3, s. e3-
Nationell ämneskategori
Medicin och hälsovetenskap
Forskningsämne
Medicin
Identifikatorer
URN: urn:nbn:se:oru:diva-11603DOI: 10.5037/jomr.2010.1303OAI: oai:DiVA.org:oru-11603DiVA, id: diva2:344157
Tillgänglig från: 2010-08-18 Skapad: 2010-08-18 Senast uppdaterad: 2017-10-18Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Personposter BETA

Ivarsson, MikaelKoskela, AnitaJohansson, Carina B.

Sök vidare i DiVA

Av författaren/redaktören
Ivarsson, MikaelKoskela, AnitaJohansson, Carina B.
Av organisationen
Hälsoakademin
Medicin och hälsovetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 522 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf