Till Örebro universitet

oru.seÖrebro universitets publikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Accuracy and reproducibility in phase contrast imaging using SENSE
Department of Biomedical Engineering, Örebro University Hospital, Örebro, Sweden; Department of Biomedical Engineering, Linköping University, Linköping, Sweden; 3Department of Medicine and Care, Division of Clinical Physiology, Linköping University, Linköping, Sweden.ORCID-id: 0000-0002-8351-3367
Department of Biomedical Engineering, Linköping University, Linköping, Sweden.
2Department of Biomedical Engineering, Linköping University, Linköping, Sweden; 3Department of Medicine and Care, Division of Clinical Physiology, Linköping University, Linköping, Sweden.
2003 (Engelska)Ingår i: Magnetic Resonance in Medicine, ISSN 0740-3194, E-ISSN 1522-2594, Vol. 50, nr 5, s. 1061-0168Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

The purpose of this study was to evaluate the accuracy and reproducibility of phase contrast imaging using the sensitivity encoding (SENSE) method at different reduction factors. Analytical expressions were derived that state how reproducibility is influenced for velocity and flow measurements. Computer simulations, and in vitro and in vivo studies were performed in order to validate these expressions and to assess how accuracy is affected when different reduction factors are applied. It was shown that reproducibility depends on the reduction and geometry factors. Since the geometry factor varies spatially, so does the reproducibility for phase contrast imaging. In areas with high geometry factors, the standard deviation (SD) may become so large that aliasing occurs. The accuracy of phase contrast imaging is not influenced directly when SENSE is used, but may be indirectly influenced due to high SDs of the measured phase that may subsequently cause aliasing. The current results show that it is possible to achieve accurate flow measurements even at high reduction factors. By taking the geometry factor into account, it may be possible to find areas where phase contrast imaging is accurate even at high reduction factors.

Ort, förlag, år, upplaga, sidor
Hoboken, USA: John Wiley & Sons, 2003. Vol. 50, nr 5, s. 1061-0168
Nyckelord [en]
Phase contrast imaging, flow quantification, SENSE, parallel MRI, reproducibility
Nationell ämneskategori
Medicin och hälsovetenskap Radiologi och bildbehandling
Identifikatorer
URN: urn:nbn:se:oru:diva-50374DOI: 10.1002/mrm.10634ISI: 000186326400020PubMedID: 14587017Scopus ID: 2-s2.0-0242322611OAI: oai:DiVA.org:oru-50374DiVA, id: diva2:930257
Tillgänglig från: 2016-05-23 Skapad: 2016-05-23 Senast uppdaterad: 2017-11-30Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Thunberg, Per

Sök vidare i DiVA

Av författaren/redaktören
Thunberg, Per
I samma tidskrift
Magnetic Resonance in Medicine
Medicin och hälsovetenskapRadiologi och bildbehandling

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 579 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf