Interobserver reliability and intraobserver reproducibility of three radiological classification systems for intra-articular calcaneal fractures
Department of Orthopedics, Sundsvall Hospital, Sundsvall, Sweden.
2011 (English)In: Foot & ankle international, ISSN 1071-1007, E-ISSN 1944-7876, Vol. 32, no 9, 861-866 p.Article in journal (Refereed) Published
Abstract [en]

Background: The management of intra-articular calcaneal fractures is difficult. One aspect for successful management is the use of a reliable and reproducible fracture classification system (FCS). The purpose of this study was to evaluate the interobserver reliability and intraobserver reproducibility of Letournel, Sanders, and Zwipp classification systems on CT scan and the Bohler's angle measurement on plain X-ray. Furthermore, we studied if the addition of a CT scan to the plain X-ray influenced the evaluation of fracture extension to the calcaneocuboid joint.

Methods: The CT scan and plain X-ray images of 51 intra-articular calcaneal fractures were evaluated two times by three observers (two radiologists and one orthopedic surgeon) within a 5-month interval. The interobserver reliability was measured using the Fleiss kappa while the intraobserver reproducibility was measured using the Cohen's kappa.

Results: The mean kappa values for the interobserver reliability and intraobserver reproducibility of the Sanders classification were 0.25 and 0.39, respectively, of Zwipp classification were 0.24 and 0.16, respectively, while those of the Letournel classification were 0.50 and 0.42, respectively. For the Böhler's angle, the mean kappa values for the interobserver reliability and intraobserver reproducibility were 0.34 and 0.32, respectively. The addition of CT scan images to plain X-ray found a higher incidence of calcaneocuboid joint involvement.

Conclusion: Clinicians should be aware of the limitation regarding the interobserver reliability and intraobserver reproducibility of the Letournel, Sanders and Zwipp classification systems for calcaneal fractures. Future studies should attempt to improve the present classification systems.

Place, publisher, year, edition, pages
Seattle, USA: American Orthopaedic Foot & Ankle Society , 2011. Vol. 32, no 9, 861-866 p.
Keyword [en]
Calcaneal Fractures, Interobserver Reliability, Intraobserver Reproducibility, Sanders Classification, Zwipp Classification, Letournel Classification, Bohler's Angle, Calcaneocuboid Joint
National Category
Medical and Health Sciences Orthopedics
Identifiers
URN: urn:nbn:se:oru:diva-55785DOI: 10.3113/FAI.2011.0861ISI: 000294513400006PubMedID: 22097161Scopus ID: 2-s2.0-80052378789OAI: oai:DiVA.org:oru-55785DiVA: diva2:1074578
Available from: 2017-02-15 Created: 2017-02-15 Last updated: 2017-10-18Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textPubMedScopus

Search in DiVA

By author/editor
Wretenberg, Per
In the same journal
Foot & ankle international
Medical and Health SciencesOrthopedics

Search outside of DiVA

GoogleGoogle Scholar

Altmetric score

Total: 87 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf