oru.sePublikationer
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
A visual grading study for different administered activity levels in bone scintigraphy
Department of Medical Physics, IMH, Linköping University, Radiation Physics UHL, County council of Östergötland, Östergötland, Sweden.
Department of Radiation Physics, Kalmar County Hospital, Kalmar, Sweden.
Department of Clinical Physiology UHL, County Council of Östergötland, Linköping, Sweden.
Örebro University Hospital. Department of Radiology.ORCID iD: 0000-0003-3253-8967
Show others and affiliations
2015 (English)In: Clinical Physiology and Functional Imaging, ISSN 1475-0961, E-ISSN 1475-097X, Vol. 35, no 3, 231-236 p.Article in journal (Refereed) Published
Abstract [en]

Introduction: The aim of the study is to assess the administered activity levels versus visual-based image quality using visual grading regression (VGR) including an assessment of the newly stated image criteria for whole-body bone scintigraphy.

Materials and methods: A total of 90 patients was included and grouped in three levels of administered activity: 400, 500 and 600 MBq. Six clinical image criteria regarding image quality was formulated by experienced nuclear medicine physicians. Visual grading was performed in all images, where three physicians rated the fulfilment of the image criteria on a four-step ordinal scale. The results were analysed using VGR. A count analysis was also made where the total number of counts in both views was registered.

Results: The administered activity of 600 MBq gives significantly better image quality than 400 MBq in five of six criteria (P<005). Comparing the administered activity of 600 MBq to 500 MBq, four criteria of six show significantly better image quality (P<005). The administered activity of 500 MBq gives no significantly better image quality than 400 Mbq (P<005). The count analysis shows that none of the three levels of administrated activity fulfil the recommendations by the EANM.

Conclusion: There was a significant improvement in perceived image quality using an activity level of 600 MBq compared to lower activity levels in whole-body bone scintigraphy for the gamma camera equipment end set-up used in this study. This type of visual-based grading study seems to be a valuable tool and easy to implement in the clinical environment.

Place, publisher, year, edition, pages
Wiley-Blackwell, 2015. Vol. 35, no 3, 231-236 p.
Keyword [en]
bone and bones, evaluation, radionuclide imaging, technetium Tc 99 m
National Category
Physiology
Identifiers
URN: urn:nbn:se:oru:diva-56419DOI: 10.1111/cpf.12155ISI: 000352726400010PubMedID: 24797289Scopus ID: 2-s2.0-84926513739OAI: oai:DiVA.org:oru-56419DiVA: diva2:1082264
Note

Funding Agency:

County Council of Östergotland, Sweden

Available from: 2017-03-16 Created: 2017-03-16 Last updated: 2017-10-18Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textPubMedScopus

Search in DiVA

By author/editor
Geijer, Håkan
By organisation
Örebro University Hospital
In the same journal
Clinical Physiology and Functional Imaging
Physiology

Search outside of DiVA

GoogleGoogle Scholar

Altmetric score

Total: 85 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf