Övergå till högre stålhållfasthet
Örebro University, School of Science and Technology.
Örebro University, School of Science and Technology.
2017 (Swedish)Independent thesis Basic level (professional degree), 10 credits / 15 HE creditsStudent thesisAlternative title
Switch to higher steel strength (English)
Abstract [sv]

Detta projekt handlar om en övergång till högre stålhållfasthet. Övergången sker från

stålhållfastheten S355 till S690 i HEA-profiler för pelare samt vindbockar. Valet att

genomföra detta projekt kommer ifrån att det skulle vara intressant att se om det finns några

vinster med att övergå till högre stålhållfasthet.

Under projektets gång kunde det konstateras att mindre stålprofiler kunde väljas vid val av

S690 istället för den traditionella S355. För just denna specifika stålhall som undersöktes

minskades pelarstorleken med tre pelarprofiler. Medan för vindbockarna kunde endast en

pelarprofil minskas.

Vid användning av stålhållfastheten S690 uppnås tvärsnittklass 4 för ett fåtal HEA-profiler.

Detta medför till mer omfattande dimensioneringsutförande jämfört med stålhållfastheten

S355 som endast når tvärsnittsklass 3 som högst.

Det föreligger för tillfället ett ekonomiskt incitament för att välja högre stålhållfasthet enligt

de approximerade kostnadsanalyser som verkställdes under projektets gång.

Med den högre stålhållfastheten blir stålmängden lägre för stålhallen. Detta medför mindre

transporter till byggarbetsplatsen, vilket är gynnsamt både ur ett miljöperspektiv och

ekonomiskt perspektiv.

Abstract [en]

This project is about a transition to higher steel strength. The transition is from steel strength

S355 to S690 in HEA- profiles for column and wind trestles. The choice to do this project

comes from the fact that it would be interesting to see if there are any profits in switching to

higher steel strength.

During the project process it was found that smaller steel profiles could be chosen when S690

was selected instead of the traditional S355. For this particular steel hall the column size was

reduced by three column profiles and for the wind trestles only one profile could be reduced.

When the steel strength S690 is used, the cross class 4 is obtained for a few HEA- profiles.

This leads to more extensive dimensioning performance compared to the steel strength S355

which reaches only the cross class 3 as the highest.

At present there is an financial incentive to choose higher steel strength according to the

approximate cost analyzes carried out during the project process.

With the higher steel strength, the steel amount becomes lower for the steel hall. This leads to

less transport to the construction site. Which is beneficial both for an environmental

perspective and economic perspective.

Place, publisher, year, edition, pages
2017. , 156 p.
Keyword [en]
HEA-profiles, higher steel strength, cost, amount of steel
Keyword [sv]
HEA-profil, högre stålhållfasthet, kostnad, stålmängd
National Category
Civil Engineering
Identifiers
URN: urn:nbn:se:oru:diva-58312OAI: oai:DiVA.org:oru-58312DiVA: diva2:1115847
Subject / course
Construction Engineering
Supervisors
Examiners
Available from: 2017-06-27 Created: 2017-06-27 Last updated: 2017-06-27Bibliographically approved

Open Access in DiVA

fulltext(2483 kB)7 downloads
File information
File name FULLTEXT01.pdfFile size 2483 kBChecksum SHA-512
043766210d7283428c9cfcfb5b9ffb2f6612bd6c6aa916fdf9dac4f6948111e524c1c4cad97746365c442d1ecd24109c20e26b64cebd29ba7b9c7baf0338d0f0
Type fulltextMimetype application/pdf

By organisation
School of Science and Technology
Civil Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 7 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Total: 35 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf