TEST AV NYA GIVARE FÖR FUKTMÄTNING I BETONG- Mätutrustning kring relativ fuktutveckling i betong
Örebro University, School of Science and Technology.
Örebro University, School of Science and Technology.
2019 (Swedish)Independent thesis Basic level (degree of Bachelor of Fine Arts), 10 credits / 15 HE creditsStudent thesisAlternative title
TESTING OF SENSORS FOR MOISTURE MEASUREMENT WITHIN CONCRETE  - Equipment surrounding moisture development within concrete (English)
Abstract [sv]

SAMMANFATTNING Uttorkningen hos betongen har länge varit en fråga som inte tycks ha någon bra lösning, framförallt gäller det uppföljningen av den. Betongproducenter satsar idag på låga vct för att hålla ner uttorkningstiderna och samtidigt öka betongens hållfasthet. Uttorkningen är speciellt viktig, vid föreliggande uttorkningskrav, för när ytmaterial kan appliceras med hänsyn till dess relation till den relativa fuktigheten, RF, hos betongen och styr till stor del tidplanerna på bygget. Problematiken ligger egentligen i att betongproducenterna inte har konkret vetskap kring duglig mätutrustning som följer utvecklingen av den relativa fuktigheten hos betong. Producenterna satsar mer och mer påegnaexperimentförhurdennaskallföljasupppåbästamöjligasättochdennarapport är ytterligare ett exempel på just det. Syftet korrigerades och anpassades efter den tidspress som uppstått under arbetets gång. Från att egentligen havarituteefterhelttrådlösaochingjutningsbarasensorerövergicksdettillattutföratester med sensorer utan krav på trådlöshet. Potentiell mätutrustning togs fram i syfte att testas ochjämförasmotaktuellamätmetoderförattmäta RF i betong. Utrustningen som användes för dem praktiska testerna var sensorerna, HYT 271 och HYT 221, tillverkade av ​IST AG​. Erhållna värden skulle därefter jämföras mot RBK-mätning där givaren Vaisala valdes ut. Praktiska simuleringar för arbetet utfördes i orten Kungsör där mätutrustningen avgränsades till elektroniska verktyg och självkompakterande betong användes. Utförda mätningar med sensornHYT 221 rapporterades inte i rapporten. Sensorn slutade att fungera efter en timme (1 hr) och kunde temporärt konstateras död. När sensorn sedan avlägsnats efter härdning på tre (3) dygn och monterats tillbaka fungerade den utan problem. I och med detta kunde inte jämförelser mellan HYT sensorn och RBK-givaren fullbordas i rapportens syfte. Slutsatsen för resultatet var att sensornvisatsfulltdugligmenintefungeratienlighetmedsyftetsomi sin tur gett förlorad avsikt för jämförbar RBK-mätning. Därtill behövde sensorn avlägsnas för att aktiveras igen där miljön av den omgivande färska betongen tros havaritförpåfrestande.Avnämnda anledningar fastställs utvald mätutrustning vara opraktisk för förfarandet,samtliknandeförsök.Ingen smidighet tycks finnas hos produkten för uttänkt syfte, produkten acklimatiseras således ej för utförandet.

Abstract [en]

The drying of concrete continues to be a topic that doesn’t seem to have any good solutions, in particular the wayinfollowitupduringproductionandonsite.Concreteproducers,today,investalot of effort with concrete produced with a low water-cement ratio. This enables themtokeepthedrying times down and at the same time produce concrete with goodstrength.Thedryingtimeofconcreteis of importance as to when materials can be applied to concretewhichrelatestorelativehumidity,RH, within the concrete. The problem lays in the producers nothavingenoughknowledgeofgoodequipmentforfollowingthe relative humidity in the concrete. This has made the producers strengthen theirknowledgeinthearea by conducting their own tests with different measurement equipment that followstheRH.Thisreport is another example of that. The purpose of the report was corrected and adapted due to the time pressure that arose during the work. From having actually been looking for fully wireless and embedded sensors, it was made to perform tests with sensors without the need for wirelessness. Potential equipment was evaluated, tested and compared to present methods and equipments for following the RH in the concrete. The equipment that was used for the practical test were sensors, HYT 271 and HYT 221, developed by IST AG who specialises in the area. The results were then supposed to be compared to a present, RBK-sensor and method, to ensure the sensors reliability. The practical tests were executed in Kungsör and the measurement equipment were limited to electronic devices.Becauseofits’easyhandlingself-compactingconcretewasused.Thetestswiththe HYT 221 were not documented in this report due to the timeframe for the report. The sensor stopped working after approximately an hour and was temporarily stated not working, though it was later confirmed as working. After three (3) days when the sensor was removed and remounted, it was fully functional again. ​Thus, comparisons between the HYT sensor and the RBK-sensor could therefore not be completed accordingly to the purpose of the report. The conclusion is that the sensor is fully useable but didn’t satisfy the sought purpose which initself made the comparable RBK-tests irrelevant. In addition, the sensor needed to be removed and reactivated. The reason for that is believed to be the strenuous environment in the fresh concrete. Based on that conclusion the equipment is stated useless for the execution and inconvenient to use, therefore the product doesn´t acclimate for such execution. 

Place, publisher, year, edition, pages
2019. , p. 41
Keywords [en]
Relative humidity, moisture development, drying time, surface coating, measuring methods, measuring equipment, concrete sensors, embedded, Rådet för Byggkompetens (RBK).
Keywords [sv]
Relativ fuktighet, fuktutveckling, uttorkningstider, ytmaterial, mätmetod, mätutrustning, borrhålsmätning, sensor, ingjutningsbar, Rådet för Byggkompetens.
National Category
Civil Engineering
Identifiers
URN: urn:nbn:se:oru:diva-74943OAI: oai:DiVA.org:oru-74943DiVA, id: diva2:1334003
Subject / course
Construction Engineering
Supervisors
Examiners
Available from: 2019-07-02 Created: 2019-07-02 Last updated: 2019-07-02Bibliographically approved

Open Access in DiVA

No full text in DiVA

By organisation
School of Science and Technology
Civil Engineering

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 23 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf