Improved Retention and Bone-to-Implant Contact with Fluoride-Modified Titanium Implants
Örebro University, Department of Clinical Medicine.
2004 (English)In: International Journal of Oral & Maxillofacial Implants, ISSN 0882-2786, E-ISSN 1942-4434, Vol. 19, no 5, p. 659-666Article in journal (Refereed) Published
Abstract [en]

Purpose: The purpose of the present study was to investigate whether a fluoride modification of the titanium surface would have an effect on bone response after implantation. Materials and Methods: Titanium-oxide–blasted titanium implants with and without fluoride modification were investigated in a rabbit tibia model. Quantitative analysis of surface roughness, biomechanical interlocking, and in vivo tissue reactions in rabbit bone at 1 and 3 months after placement were compared. Results: The fluoride-modified test implants had a slightly smoother surface (Sa: 0.91 ± 0.14 µm) than the unmodified control implants (Sa: 1.12 ± 0.24 µm). Significantly higher removal torque values (85 ± 16 Ncm vs 54 ± 12 Ncm) and shear strength between bone and implants (23 ± 9 N/mm2 vs 15 ± 5 N/mm2) were measured for the fluoride-modified implants after 3 months. The histomorphometric evaluations demonstrated higher bone-to-implant contact for test implants at 1 month (35% ± 14% vs 26% ± 8%) and 3 months (39% ± 11% vs 31% ± 6%) after placement. Discussion: Implant surface modification with fluoride may result in morphologic and physiochemical phenomena that are of significance for the bone response. Another possible explanation for the findings in the present study is that a surface modification changes the surface chemical structures to be more suitable for bone bonding. Conclusion: Based on the biomechanical and histomorphometric data, the fluoride-modified titanium implants demonstrated a firmer bone anchorage than the unmodified titanium implants. These implants achieved greater bone integration than unmodified titanium implants after a shorter healing time. (More than 50 references.)

Place, publisher, year, edition, pages
Chicago, Ill.]: Quintessence Pub. Co. , 2004. Vol. 19, no 5, p. 659-666
National Category
Medical and Health Sciences
Research subject
Medicine
Identifiers
URN: urn:nbn:se:oru:diva-4344OAI: oai:DiVA.org:oru-4344DiVA, id: diva2:138643
Available from: 2008-02-19 Created: 2008-02-19 Last updated: 2017-12-14Bibliographically approved

Open Access in DiVA

No full text in DiVA

Authority records BETA

Johansson, Carina B.

Search in DiVA

By author/editor
Johansson, Carina B.
By organisation
Department of Clinical Medicine
In the same journal
International Journal of Oral & Maxillofacial Implants
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 179 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf