oru.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Histologic evaluation of bone response to oxidized and turned titanium micro-implants in human jawbone
Örebro University, Department of Health Sciences. Örebro University, Department of Clinical Medicine.
2003 (English)In: International Journal of Oral & Maxillofacial Implants, ISSN 0882-2786, E-ISSN 1942-4434, Vol. 18, no 3, p. 341-348Article in journal (Refereed) Published
Abstract [en]

PURPOSE:

To evaluate the human bone tissue response to 2 surfaces (oxidized or turned) on commercially available titanium implants.

MATERIALS AND METHODS:

Screw-type turned (control) and oxidized (test) micro-implants were manufactured in the same manner as commercially available turned and oxidized (TiUnite, Brånemark System) implants. The thickness of the oxide layer of the test implants was on average 10 microm, corresponding to the oxide thickness of the apical part of the TiUnite implant. Twenty patients received 1 test and 1 control micro-implant each during implant surgery. Before placement, the surface topography of the implants was characterized with an optical confocal laser profilometer. After a mean healing period of 6.6 months in the maxilla and 3.5 months in the mandible, the micro-implants and surrounding tissue were removed with a trephine bur. Histologic sections were produced, and the specimens were analyzed histomorphometrically.

RESULTS:

Surface roughness and enlargement were greater for the oxidized implants than for the turned implants. All micro-implants, except for 2 controls, were found to be clinically stable at the time of retrieval. Histomorphometric evaluation demonstrated significantly higher bone-to-implant contact for the oxidized implants, whether placed in the maxilla or in the mandible. Significantly more bone was found inside the threaded area for the oxidized implants placed in the mandible and maxilla, but there was no difference between implants with regard to position (maxilla or mandible).

DISCUSSION:

The stronger bone response to the oxidized implants may have contributed to the fact that 2 control implants but no test implants were lost. The reason for these findings may depend on one or multiple differences of the surfaces between test and control implants: (1) the thicker oxide layer itself, (2) increased surface roughness, (3) different surface morphology in terms of porosity, or (4) change in crystal structure.

CONCLUSION:

The present histologic study in human jawbone demonstrated a significantly higher bone response for anodic oxidized titanium implants than for implants with a turned surface.

Place, publisher, year, edition, pages
2003. Vol. 18, no 3, p. 341-348
National Category
Medical and Health Sciences
Research subject
Medicine
Identifiers
URN: urn:nbn:se:oru:diva-4349OAI: oai:DiVA.org:oru-4349DiVA, id: diva2:138648
Available from: 2008-02-19 Created: 2008-02-19 Last updated: 2017-12-14Bibliographically approved

Open Access in DiVA

No full text in DiVA

Authority records BETA

Johansson, Carina B.

Search in DiVA

By author/editor
Johansson, Carina B.
By organisation
Department of Health SciencesDepartment of Clinical Medicine
In the same journal
International Journal of Oral & Maxillofacial Implants
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 80 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf