Retrieved implants from irradiated sites in humans: A histologic/histomorhpometric investigation of oral and craniofacial implants
Örebro University, Department of Clinical Medicine.
Show others and affiliations
2006 (English)In: Clinical Implant Dentistry and Related Research, ISSN 1523-0899, E-ISSN 1708-8208, Vol. 8, no 3, p. 142-150Article in journal (Refereed) Published
Abstract [en]

Purpose The aim of this report was to quantitatively and qualitatively evaluate the tissue response to bone-anchored implants retrieved from irradiated sites in patients.

Materials and Methods The material consists of 23 consecutively received Brånemark® implants (Nobel Biocare AB, Göteborg, Sweden) placed in pre- or postoperatively irradiated sites. Twenty-two of the 23 implants were suitable for histologic evaluation of undecalcified sections in the light microscope.

Results The oral implants with shorter time in situ demonstrated sparse bone to implant contact with mainly dense connective tissue in the interface. However, for implants with longer time in situ, high amounts of bone-implant contact and bone fill of threads were noted. The mean values of bone-implant contact and bone area within the thread were calculated to 40% (16–94) and 70% (13–96), respectively. The craniofacial implants, with the exception of two implants lined with a capsular formation, demonstrated mature and newly formed bone at the bone-implant interface. The mean value for bone-metal contact was calculated to 45 and 53% for two specimens. The mean value for bone area within the thread ranged from 65 to 88% for three specimens.

Conclusion The possibility to achieve bone anchorage of implants in irradiated tissue was supported by the findings in this study. However, due to limited material, conclusions with regard to radiation dose and bone tissue response to implants cannot be stated.

Place, publisher, year, edition, pages
Hamilton, Ont.: B.C. Decker , 2006. Vol. 8, no 3, p. 142-150
National Category
Medical and Health Sciences
Research subject
Medicine
Identifiers
URN: urn:nbn:se:oru:diva-4362DOI: 10.1111/j.1708-8208.2006.00010.xOAI: oai:DiVA.org:oru-4362DiVA, id: diva2:138661
Available from: 2008-02-19 Created: 2008-02-19 Last updated: 2017-12-14Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full text

Authority records BETA

Johansson, Carina B.

Search in DiVA

By author/editor
Johansson, Carina B.
By organisation
Department of Clinical Medicine
In the same journal
Clinical Implant Dentistry and Related Research
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 45 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf