Evaluations of Bone Tissue Integration to Pure and Alloyed Titanium Implants
Örebro University, Department of Health Sciences.
2008 (English)In: Clinical Implant Dentistry and Related Research, ISSN 1523-0899, E-ISSN 1708-8208, Vol. 10, no 3, p. 191-199Article in journal (Refereed) Published
Abstract [en]

Purpose: This study was performed for comparisons of tissue integration to commercially pure (CP) and titanium-6-aluminum-4 vanadium (Ti-6-Al-4V) implants using various existing three-dimensional biomechanical and two-dimensional histomorphometrical techniques, and to monitor the loosening torque during in vivo removal torque (RTQ) test with a novel unit not used before in a pilot study in rabbits.

Materials and Methods: The implants were topographically characterized and inserted in femurs and tibiae of five rabbits (in total 40 implants, 20 per group). After 16 weeks, the implant integration was biomechanically evaluated by: (1) resonance frequency test, and (2) peak RTQ test and the graph from the monitoring curve. Biopsies of the implants in situ were processed to undecalcified cut and ground sections followed by light microscopical quantifications. Shear strength calculations were performed.

Results: Significantly higher mean value of RTQ (p = .01) and shear strength tests (p = .03) were observed for the CP titanium implants compared to Ti-6-Al-4V implants. The monitoring curve from the RTQ test demonstrated no differences in the shape or form that could provide further information about the differences in the implant-to-bone attachment.

Conclusions: The CP titanium implants showed increased RTQ and shear strength values compared to the Ti-6-Al-4V implants. The new tool of monitoring the RTQ curve could not demonstrate differences between the two materials. The exact influence of the implant materials on the surrounding tissues needs to be further investigated.

Place, publisher, year, edition, pages
2008. Vol. 10, no 3, p. 191-199
National Category
Medical and Health Sciences Surgery Surgery
Research subject
Surgery
Identifiers
URN: urn:nbn:se:oru:diva-4371DOI: 10.1111/j.1708-8208.2007.00077.xOAI: oai:DiVA.org:oru-4371DiVA, id: diva2:138670
Available from: 2008-02-19 Created: 2008-02-19 Last updated: 2017-12-14Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full text

Authority records BETA

Johansson, Carina B

Search in DiVA

By author/editor
Johansson, Carina B
By organisation
Department of Health Sciences
In the same journal
Clinical Implant Dentistry and Related Research
Medical and Health SciencesSurgerySurgery

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 36 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf