To Örebro University

oru.seÖrebro University Publications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Bestämning av vänster kammares ejektionsfraktion med 2-dimensionell och 3-dimensionell ekokardiografi
Örebro University, School of Health Sciences.
2020 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesisAlternative title
Determination of left ventricle ejectionsfraction with 2-dimensional and 3-dimensional echocardiography (English)
Abstract [sv]

Vänster kammares ejektionsfraktion (VKEF) är ett mått på hur stor andel av den diastoliska kammarvolymen som pumpas ut under systole. Två dimensionell ekokardiografi (2DE) är numera den mest användbara metoden för bestämning av VKEF med hjälp av Simpson biplanmetod. Eftersom Simpson biplanmetod gör geometrisk antagande vid bedömning av VK-form, kräver god erfarenhet och tar tid för optimal bildsamling, kan denna kombination visa sig vara problematisk. Med tre dimensionell ekokardiografi HeartModel (3DEHM) kan beräknas VKEF och geometrisk antagande av VK-form undvikas dock kräver metoden en bra 2DE bildkvalité. Syftet med studien är att undersöka hjärtat med ekokardiografi för att jämföra median för VKEF mellan 3DEHM och 2DE Simpson biplane. Studien omfattade 28 hjärtfriska testpersoner både män och kvinnor. Testpersonerna undersökts med ultraljud av hjärtat och VKEF beräknades med de två metoderna. Wilcoxon signed-rank test gjordes för att påvisa om det förelåg signifikant skillnad för median mellan de två metoderna. Resultatet visade att det förelåg en signifikant skillnad för median mellan de två metoderna vid bestämning av VKEF. VKEF med 2DE Simpson biplanmetod var lägre än 3DEHM 7%. Med både metoderna erhåll några mätvärden som hamnade inom lätt sänkt gränsen av VKEF. Slutsatsen för studien är att det är oklart vilken av de metoderna är rätt för bestämning av VKEF, detta resultat måste valideras mot annan metod som Magnetisk resonanstomografi (MR).

Abstract [en]

The left ventricle ejection fraction (LVEF) is a measure of the proportion of diastolic ventricle volume pumped out during systole. Two-dimensional echocardiography (2DE) is now the most useful method for determining LVEF using the Simpson biplane. Since the 2DE Simpson biplane makes geometric assumption for assessing LV shape, requires good experience and takes the time for optimal image collection, this combination can prove to be problematic. With three-dimensional echocardiography HeartModel (3DEHM) can LVEF calculate and geometric assumption of LV shape avoided but3DEHM method requires good 2DE image quality. The purpose of the study is to examine the heart with echocardiography to compare LVEF for median between 3DEHM and 2DE Simpson biplane. The study included 28 heart-healthy volunteers both men and women. They were examined with ultrasound of heart and LVEF was calculated using the two methods. The Wilcoxon Singed Rank test was performed to determine if there was a significant difference in the median between the two methods for determining LVEF. The result showed that there was significant difference for median between the two methods. EF with 2DE Simpson lower than 3DEHM 7%. With both methods obtain some measurement values that fell within the slightly lowered limit of LVEF. The conclusion of the study is that it is unclear which of the methods is right to find the LVEF, this result must be validated against another method such as Magnetic Resonance Tomography (MRT).

Place, publisher, year, edition, pages
2020.
Keywords [en]
2dimensional echocardiography Simpson biplane, 3-dimensional echocardiography, ejection fraction and bildkvalite
Keywords [sv]
dimensionell ekokardiografi Simpson biplane, 3 dimensionell ekokardiografi Heart Model, ejektionsfraktion, bildkvalité
National Category
Biomedical Laboratory Science/Technology
Identifiers
URN: urn:nbn:se:oru:diva-84600OAI: oai:DiVA.org:oru-84600DiVA, id: diva2:1454213
Subject / course
Biomedicinsk laboratorievetenskap
Supervisors
Examiners
Available from: 2020-07-15 Created: 2020-07-15 Last updated: 2020-07-15Bibliographically approved

Open Access in DiVA

No full text in DiVA

By organisation
School of Health Sciences
Biomedical Laboratory Science/Technology

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 1331 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf