To Örebro University

oru.seÖrebro University Publications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Deep learning based digitisation of prostate brachytherapy needles in ultrasound images
Örebro University, School of Medical Sciences.
Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, Sweden.
Örebro University, School of Medical Sciences. Örebro University Hospital. Department of Medical Physics.ORCID iD: 0000-0002-8351-3367
Örebro University, School of Medical Sciences. Örebro University Hospital. Department of Medical Physics, Faculty of Medicine and Health, Örebro University, Örebro, Sweden; Department of Medical Physics, Karlstad Central Hospital, Karlstad, Sweden.ORCID iD: 0000-0001-6389-7773
2020 (English)In: Medical physics, E-ISSN 2473-4209, Vol. 47, no 12, p. 6414-6420Article in journal (Refereed) Published
Abstract [en]

PURPOSE: To develop, and evaluate the performance of, a deep learning based 3D convolutional neural network (CNN) artificial intelligence (AI) algorithm aimed at finding needles in ultrasound images used in prostate brachytherapy.

METHODS: Transrectal ultrasound (TRUS) image volumes from 1102 treatments were used to create a clinical ground truth (CGT) including 24422 individual needles that had been manually digitised by medical physicists during brachytherapy procedures. A 3D CNN U-net with 128x128x128 TRUS image volumes as input was trained using 17215 needle examples. Predictions of voxels constituting a needle were combined to yield a 3D linear function describing the localisation of each needle in a TRUS volume. Manual and AI digitisations were compared in terms of the root-mean-square distance (RMSD) along each needle, expressed as median and interquartile range (IQR). The method was evaluated on a dataset including 7207 needle examples. A subgroup of the evaluation data set (n=188) was created, where the needles were digitised once more by a medical physicist (G1) trained in brachytherapy. The digitisation procedure was timed.

RESULTS: The RMSD between the AI and CGT was 0.55 (IQR: 0.35-0.86) mm. In the smaller subset, the RMSD between AI and CGT was similar (0.52 [IQR: 0.33-0.79] mm) but significantly smaller (p<0.001) than the difference of 0.75 (IQR: 0.49-1.20) mm between AI and G1. The difference between CGT and G1 was 0.80 (IQR: 0.48-1.18) mm, implying that the AI performed as well as the CGT in relation to G1. The mean time needed for human digitisation was 10 min 11 sec, while the time needed for the AI was negligible.

CONCLUSIONS: A 3D CNN can be trained to identify needles in TRUS images. The performance of the network was similar to that of a medical physicist trained in brachytherapy. Incorporating a CNN for needle identification can shorten brachytherapy treatment procedures substantially.

Place, publisher, year, edition, pages
Wiley-Blackwell Publishing Inc., 2020. Vol. 47, no 12, p. 6414-6420
Keywords [en]
Brachytherapy, Deep-learning, High-dose-rate, Image segmentation, Needle digitisation
National Category
Radiology, Nuclear Medicine and Medical Imaging
Identifiers
URN: urn:nbn:se:oru:diva-86206DOI: 10.1002/mp.14508ISI: 000583538300001PubMedID: 33012023Scopus ID: 2-s2.0-85098531928OAI: oai:DiVA.org:oru-86206DiVA, id: diva2:1473523
Note

Funding Agencies:

Nyckelfonden  OLL-787911

Region Örebro Research committee  OLL-911031

Available from: 2020-10-06 Created: 2020-10-06 Last updated: 2024-03-06Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMedScopus

Authority records

Andersén, ChristofferThunberg, PerH. Lagerlöf, Jakob

Search in DiVA

By author/editor
Andersén, ChristofferThunberg, PerH. Lagerlöf, Jakob
By organisation
School of Medical SciencesÖrebro University Hospital
Radiology, Nuclear Medicine and Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 738 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf