To Örebro University

oru.seÖrebro University Publications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Validity and reliability of physical activity measures in multiple sclerosis
Department of Neuroscience, Section for Physiotherapy, Uppsala, Sweden.
Department of Neuroscience, Section for Physiotherapy, Uppsala, Sweden.
Department of Neuroscience, Section for Physiotherapy, Uppsala, Sweden.
Department of Neuroscience, Section for Physiotherapy, Uppsala, Sweden.
Show others and affiliations
2023 (English)In: Physiotherapy Theory and Practice, ISSN 0959-3985, E-ISSN 1532-5040, Vol. 39, no 1, p. 137-153Article in journal (Refereed) Published
Abstract [en]

PURPOSE: The purpose was to evaluate the psychometric properties of physical activity measures in persons with multiple sclerosis (PwMS).

METHODS: Adults with multiple sclerosis were recruited, n = 30 (validation) and n = 57 (test-retest). Steps measured with PiezoRX, Yamax SW200 and ActiGraph GT9X Link (AGlink) and time in different positions measured with AGlink were validated against data from video analysis. Psychometric properties of the Physical Activity and Disability Survey - Revised Swedish version (PADS-R(Sw)) was evaluated.

RESULTS: The most valid measures were AGlink using the low-frequency extension filter, and PiezoRX with median absolute percentage errors (MeAPEs) of 0.9-3.1% and 1.3-3.3%. The MeAPEs were higher for Yamax SW200 (2.9-21.0%), AGlink display (3.6-44.8%) and AGlink normal filter (8.9-48.9%), indicating low validity. AGlink was not valid in measurements of sitting (MeAPE 12.0-12.5%) or lying (MeAPE 31.0-41.7%). The correlation between PADS-R(Sw) and AGlink steps was r = 0.492 (p = .009). The relative reliability of PADS-R(Sw) was ICC2,1 0.85 (CI 0.76-0.91), and absolute reliability was SEM 0.54.

CONCLUSION: AGlink and PiezoRX were valid measures of steps in PwMS. The questionnaire PADS-R(Sw) was valid, with high relative reliability, but its absolute reliability was unsatisfactory.

Place, publisher, year, edition, pages
Taylor & Francis, 2023. Vol. 39, no 1, p. 137-153
Keywords [en]
Exercise, multiple sclerosis, physical activity, reproducibility of results, validation studies
National Category
Physiotherapy
Identifiers
URN: urn:nbn:se:oru:diva-95328DOI: 10.1080/09593985.2021.1996498ISI: 000714815700001PubMedID: 34738486Scopus ID: 2-s2.0-85118577741OAI: oai:DiVA.org:oru-95328DiVA, id: diva2:1609244
Funder
Norrbacka-Eugenia FoundationP.O. Zetterling FoundationAvailable from: 2021-11-08 Created: 2021-11-08 Last updated: 2025-02-11Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMedScopus

Authority records

Nilsagård, Ylva

Search in DiVA

By author/editor
Nilsagård, Ylva
By organisation
School of Health SciencesÖrebro University Hospital
In the same journal
Physiotherapy Theory and Practice
Physiotherapy

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 147 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf