The clinical effectiveness of the corrected nose-earlobe-xiphoid distance formula in determining the internal length of a nasogastric tube in adults: A retrospective study
2024 (English)In: Intensive & Critical Care Nursing, ISSN 0964-3397, E-ISSN 1532-4036, Vol. 85, article id 103783Article in journal (Refereed) Published
Abstract [en]
INTRODUCTION: Accurate determination of the internal length of nasogastric tubes is essential for the safe and effective completion of blind insertions, a routine nursing procedure. The widely used nose-earlobe-xiphoid distance lacks evidence and effectiveness. A recent randomized controlled trial proposed an alternative, the corrected nose-earlobe-xiphoid distance formula. However, its effectiveness in real-world clinical practice has not yet been studied.
OBJECTIVE: This study assessed the real-world clinical effectiveness of the corrected nose-earlobe-xiphoid distance formula for determining the internal nasogastric tube length in adult patients admitted to hospitalization or intensive care units. DESIGN: A single-center retrospective clinical effectiveness study was conducted, utilizing routinely collected observational data.
SETTING AND MAIN OUTCOME MEASURES: Between October 2020 and November 2022, 358 adult patients in a general hospital requiring a nasogastric feeding tube were included. The primary outcome involved assessing nasogastric tube tip positioning (>3 cm below the lower esophageal sphincter) by an advanced practice nurse through X-ray verification. Secondary outcomes, obtained from patient records for a random subgroup of 100 participants, were reporting clarity and evaluation of the tip position by reviewing radiologists.
RESULTS: Following evaluation by an advanced practice nurse, all nasogastric feeding tubes were determined to be correctly positioned. Among the subgroup of 100 tubes, X-ray protocols, as documented by the reviewing radiologists, showed varying levels of reporting clarity for the tube tip: 4.0 % lacked reporting, 33.0 % had ambiguous reporting and 63.0 % had unambiguous reporting.
CONCLUSION: The corrected nose-earlobe-xiphoid distance formula demonstrates potential to emerge as a safer alternative to existing methods for determining the internal length of nasogastric tubes.
IMPLICATIONS FOR CLINICAL PRACTICE: In addition to healthcare provider education and training, a checklist-based framework is recommended for radiologists to unambiguously report nasogastric tube tip positions.
Place, publisher, year, edition, pages
Elsevier, 2024. Vol. 85, article id 103783
Keywords [en]
Adult, Enteral nutrition, Gastrointestinal intubation, Nasogastric tube, Patient safety, X-ray
National Category
Nursing
Identifiers
URN: urn:nbn:se:oru:diva-115450DOI: 10.1016/j.iccn.2024.103783ISI: 001292816600001PubMedID: 39121690Scopus ID: 2-s2.0-85200556991OAI: oai:DiVA.org:oru-115450DiVA, id: diva2:1889526
2024-08-152024-08-152024-08-29Bibliographically approved