oru.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Urinary stone size estimation: Can we reduce the reader variations?
Örebro University, School of Health and Medical Sciences, Örebro University, Sweden.
Örebro University, School of Medicine, Örebro University, Sweden.
Örebro University, School of Health and Medical Sciences, Örebro University, Sweden.ORCID iD: 0000-0003-3253-8967
(English)Manuscript (preprint) (Other academic)
National Category
Radiology, Nuclear Medicine and Medical Imaging
Research subject
Radiology
Identifiers
URN: urn:nbn:se:oru:diva-30363OAI: oai:DiVA.org:oru-30363DiVA, id: diva2:643938
Available from: 2013-08-29 Created: 2013-08-29 Last updated: 2017-10-17Bibliographically approved
In thesis
1. The stack mode review of volumetric datasets: applications for urinary stone disease
Open this publication in new window or tab >>The stack mode review of volumetric datasets: applications for urinary stone disease
2013 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

During the last decades the acquisition and visualization of radiological images have rapidly evolved. The increasing amounts of volumetric image data particularly from modern CT systems necessitate a constant evolution of the radiological visualization techniques.

The dominating display mode for volumetric images has been the stack mode display since its introduction in computerized image review. In the increasing amounts of image data, the stack mode display needs to be analyzed so that the information content in the high resolution datasets can be transformed into clinically relevant information for the management of the individual patient. In the present thesis some aspects of the stack mode display were analyzed using for the most part the size estimation of urinary stones in unenhanced CT as a model.

The estimated size has an important correlation to the prognosis for spontaneous passage of an obstructing ureteral stone. In the present thesis the reader variations in the size estimation of urinary stones were quantified, using different visualization parameters and after an attempt to reduce the variations with a training session for the readers. The influence on the estimated stone size of CT image post processing parameters was quantified. A segmentation algorithm was developed and demonstrated to reduce the reader variability through reader independent computer aid. One limitation of the stack mode display concerns three-dimensional shapes, which was modeled by a comparison between the estimated length and width of urinary stones in two- and three-dimensional segmentation. The increasing number of image slices in the acquisitions introduces a need for efficient navigation of the image volumes. In the present thesis the navigation of CT datasets using different user interface devices was evaluated.

The rapid evolution of the MRI and CT systems necessitates a constant refinement and evaluation of the cornerstone for radiological volumetric reviewing – the stack mode display of volumetric datasets.

Place, publisher, year, edition, pages
Örebro: Örebro universitet, 2013. p. 61
Series
Örebro Studies in Medicine, ISSN 1652-4063 ; 91
Keywords
stack mode display, image visualization, image perception, computed tomography, urinary stones, urolithiasis, PACS
National Category
Radiology, Nuclear Medicine and Medical Imaging
Research subject
Medicine
Identifiers
urn:nbn:se:oru:diva-30324 (URN)978-91-7668-948-6 (ISBN)
Public defence
2013-10-04, Bohmanssonsalen, Universitetssjukhuset i Örebro, Örebro, 09:00 (Swedish)
Opponent
Supervisors
Available from: 2013-08-26 Created: 2013-08-26 Last updated: 2017-10-17Bibliographically approved

Open Access in DiVA

No full text in DiVA

Authority records BETA

Lidén, MatsAndersson, TorbjörnGeijer, Håkan

Search in DiVA

By author/editor
Lidén, MatsAndersson, TorbjörnGeijer, Håkan
By organisation
School of Health and Medical Sciences, Örebro University, SwedenSchool of Medicine, Örebro University, Sweden
Radiology, Nuclear Medicine and Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 232 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf