Signal Processing Methods for Improvement of Environmental Perception of Persons with Deafblindness
Örebro University, School of Health and Medical Sciences, Örebro University, Sweden. Örebro University, School of Science and Technology. (Mos)ORCID iD: 0000-0003-4130-7909
2014 (English)In: Advanced Materials Research, ISSN 1022-6680, E-ISSN 1662-8985, Vol. 902, p. 398-404Article in journal (Refereed) Published
Abstract [en]

Environmental perception is a functional area that is severely limited in persons with  deafblindness (DB) who belong a category of people with severe disabilities. Monitor is a vibratory aid developed with the aim to improve environmental perception of persons with DB. The aid consists of a mobile phone with an application connected to a microphone and vibrator. Monitor picks up the sounds produced by events by microphone, processes the sound using an algorithm programmed as an application in the mobile phone and then presents the signal via the vibrator to the persons with DB to be sensed and interpreted. In previous laboratory studies, four algorithms (AM, AMMC, TR, and TRHA) were developed based on modulating, and transposing principles.

The algorithms were tested by persons with normal hearing/hearing impairment and selected as good candidates to improve vibratory identification of environmental sounds. In this on-going the algorithms are tested by 13 persons with congenital D and five persons with DB using Monitor in a realistic environment, living room, kitchen or office. Forty five recorded environmental sounds were used as test stimuli.

The subjects tested the algorithms two times, Test and Retest each including a test session

initiated by a training session. The four algorithms were tested in four days at Test and four days at Retest in total eight test days. Each test day began with a training session where a sound was presented as vibrations to be sensed by the person with the aim to remember its pattern and identity.

The 45 sounds were grouped in four groups where an specific algorithm was chosen to process an specific sound group in a specific day. At the test session a sound was presented and the person was given 5 randomly chosen sound alternatives to choose the one as represented sound. The algorithms were different for different sound groups during four different test days so all algorithms were used to process all sounds. The algorithms were tested a second time, Retest, in same way as in Test.

The mean value of identification of environmental sounds varied between 74.6% and 84.0% at Test and between 86.9% and 90.4% at Retest. The identification results at Retest were

significantly improved (p<0.01) for all algorithms after a relatively short time of training indicating a good learning effect. At Test the algorithm AM was significantly better than the algorithms AMMC and TRHA (p< 0.01) and the algorithm TR was better than TRHA (p<0.01).

The algorithms AM, AMMC, and TR were selected as good candidates to be implemented in the Monitor to improve environmental perception.

Place, publisher, year, edition, pages
Switzerland: Trans Tech Publications, 2014. Vol. 902, p. 398-404
Keywords [en]
Haptic; Vibrotactile; Signal processing; Deafblindness; Environmental perception; Deaf;
National Category
Occupational Therapy Fluid Mechanics and Acoustics
Research subject
Disability Science; Electronics; Computer Engineering
Identifiers
URN: urn:nbn:se:oru:diva-34441DOI: 10.4028/www.scientific.net/AMR.902.398OAI: oai:DiVA.org:oru-34441DiVA, id: diva2:707890
Available from: 2014-03-25 Created: 2014-03-25 Last updated: 2022-12-20Bibliographically approved

Open Access in DiVA

AMR.902.398.pdf(367 kB)477 downloads
File information
File name FULLTEXT01.pdfFile size 367 kBChecksum SHA-512
1a73f997a40901edcbd27f82558c4a1c93504506c2c2eb4693c495537219bd300a6f6e850043e0fa1fa581bb4f49024f258462f1819bde34a1c6d79a26b9c594
Type fulltextMimetype application/pdf

Other links

Publisher's full text

Authority records

Ranjbar, Parivash

Search in DiVA

By author/editor
Ranjbar, Parivash
By organisation
School of Health and Medical Sciences, Örebro University, SwedenSchool of Science and Technology
In the same journal
Advanced Materials Research
Occupational TherapyFluid Mechanics and Acoustics

Search outside of DiVA

GoogleGoogle Scholar
Total: 477 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 479 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf