oru.sePublikasjoner
Endre søk
Begrens søket
1 - 18 of 18
RefereraExporteraLink til resultatlisten
Permanent link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Treff pr side
  • 5
  • 10
  • 20
  • 50
  • 100
  • 250
Sortering
  • Standard (Relevans)
  • Forfatter A-Ø
  • Forfatter Ø-A
  • Tittel A-Ø
  • Tittel Ø-A
  • Type publikasjon A-Ø
  • Type publikasjon Ø-A
  • Eldste først
  • Nyeste først
  • Skapad (Eldste først)
  • Skapad (Nyeste først)
  • Senast uppdaterad (Eldste først)
  • Senast uppdaterad (Nyeste først)
  • Disputationsdatum (tidligste først)
  • Disputationsdatum (siste først)
  • Standard (Relevans)
  • Forfatter A-Ø
  • Forfatter Ø-A
  • Tittel A-Ø
  • Tittel Ø-A
  • Type publikasjon A-Ø
  • Type publikasjon Ø-A
  • Eldste først
  • Nyeste først
  • Skapad (Eldste først)
  • Skapad (Nyeste først)
  • Senast uppdaterad (Eldste først)
  • Senast uppdaterad (Nyeste først)
  • Disputationsdatum (tidligste først)
  • Disputationsdatum (siste først)
Merk
Maxantalet träffar du kan exportera från sökgränssnittet är 250. Vid större uttag använd dig av utsökningar.
  • 1.
    Arvidsson, Erik
    et al.
    Örebro universitet, Akademin för naturvetenskap och teknik.
    Larsson, Tord
    Örebro universitet, Akademin för naturvetenskap och teknik.
    Stridh, Göran
    Örebro universitet, Akademin för naturvetenskap och teknik.
    Energiförluster i partiellt fuktiga enstegstätade ytterväggskonstruktioner: tema: fasader och fönster2009Inngår i: Bygg & teknik, ISSN 0281-658X, nr 8, s. 28-32Artikkel i tidsskrift (Annet vitenskapelig)
  • 2.
    Gillström, Peter
    et al.
    Örebro universitet, Institutionen för teknik.
    Larsson, Tord
    Örebro universitet, Institutionen för teknik.
    Energibehov vid betning2005Inngår i: Bergsmannen med Jernkontorets annaler : nordisk branschtidning för stål-, metall-, berg- och mineralindustrierna, ISSN 0284-0448, nr 4Artikkel i tidsskrift (Annet (populærvitenskap, debatt, mm))
  • 3. Grothérus, Dag
    et al.
    Larsson, Tord
    Örebro universitet, Institutionen för teknik.
    Ventilation i medelstora och större pannhus2005Rapport (Annet vitenskapelig)
    Abstract [sv]

    Utformning av pannhus kan sammanfattas enligt nedan:

    - Luftflöde som tillförs pannhuset skall klara av att tillföra erforderlig förbränningsluft samt att kyla pannhuset.

    - Pannhusetventilationen skall utföras som mekanisk ventilation och luften bör tillföras på flera olika nivåer.

    Arbetsmiljögsstiftningen anger cirka 45 oC som högsta lokaltemperatur. Undertrycket i pannhusets nedre del bör inte vara med än 40 Pa för att personalen på ett enkelt sätt skall kunna öppna dörrar vid utrymning.

  • 4.
    Larsson, Tord
    Örebro universitet, Institutionen för teknik.
    Enkätundersökning om energibesparing och drift med solfångare2000Rapport (Annet vitenskapelig)
    Abstract [sv]

    På uppdrag av Arnes Plåtslageri AB och med hjälp av en universitetscheck från ALMI Företagspartner AB, har en enkätundersökning gjorts som gäller energibesparing samt drift och skötsel av solfångareanläggning i drift. Undersökningen har gjorts på institutionen för Teknik, Avd för bygg-, energi- och maskinteknik, Örebro universitet.

    Undersökningen visar på höga energibesparingar om man från ren vedeldning går över till kombinationen ved och solvärme kombinerat i en ackumulatortank. Driftarbetet och skötseltiden förkortas samtidigt.

    Energibesparingen från en solvärmeanläggning vars primära värmekälla är ved eller olja är 1,7 - 2,3 gånger större än vad solfångaren kan leverera i producerad solvärme. Normala dimensioneringskriterier för solfångare är 400 kWh/m2 och år vid en medeltemperatur¬differens på 50 oC. Enkätundersökningen visar på en besparing på 650 - 900 kWh/ m2 och år. Att energibesparingen i undersökningen per m2solfångare är större än vad solfångarna teoretiskt kan producera i värme, beror bl a på befintliga systems relativt dåliga system¬verkningsgrader under det varma delen av året, som då kan gå ned till 30%. Undersökningen har även tydligt visat att det är skillnad på energibehov och köpt/tillförd energi i form av ved eller olja.

    Rapporten rekommenderar att noggrannare mätningar utförs för att erhålla mer exakta siffervärden.

  • 5.
    Larsson, Tord
    Örebro universitet, Institutionen för teknik.
    Halléns ekvation - varaktigheten för uteluft: godhetstal : teknik och forskning2008Inngår i: Energi & miljö, ISSN 1101-0568, nr 2, s. 71-72Artikkel i tidsskrift (Annet vitenskapelig)
    Abstract [sv]

    Tomas Hallén (1981) har beskrivit ett matematiskt samband för varaktigheten för utetemperatur. Detta samband har ett flertal konsulter använt i olika datorprogram för att beräkna energibesparing vid olika typer av energisystem, såsom värmepumpar och värmeåtervinning, om värmelasten är utetemperaturberoende.

    Godhetstal för Halléns ekvation är på R2=0,95, om man gör en analogi med att använda minsta kvardratmetoden. Det är visat att Halléns ekvations för utetemperaturens varaktighet stämmer mycket bra med den graf som är förlaga och kan med god precition användas i energiberäkningarna.

  • 6.
    Larsson, Tord
    Örebro universitet, Akademin för naturvetenskap och teknik.
    Indirekt mätning av rördrommens Botaurus stellaris, trastsångarens Acrocephalus arundinaceus och näktergalens Luscinia luscinia ljudeffektsnivå2010Inngår i: Fåglar i Kvismaren: årsskrift 2009, Örebro: Föreningen Kvismare fågelstation , 2010, nr 156Kapittel i bok, del av antologi (Annet vitenskapelig)
    Abstract [en]

    The purpose of this article is to compare the sound power level of the following birds: Bittern (Botaurus stellaris), Great Reed Warbler (Acrocephalus arundinaceus) and Thrush Nightingale (Luscinia luscinia). The results are achieved by using a new indirect measurement method. This method calculates measurements, using the frequency level of the singing birds as heard by the listening person and the distance of the bird from that same person. 

    In this instance, three examples are used for the calculations; Bittern at a distance of 10.4 km, Great Reed Warbler at a distance of 0.5 - 0.7km and Thrush Nightingale at a distance of 0.7km. The lowest sound power will be achieved, if the 'Bird sound spread' can be at 180 degs semi-circle radiating from the bird. At the chosen distances the following values are obtained: Bittern - 88 db, Thrush Nightingale - 74 db and Great Reed Warbler - 65 db. The biggest uncertainty in obtaining these measurements is the accuracy of the Sound Pressure Loudness Level on the Phonograph and the difficulties of the distance from the bird.

     

  • 7.
    Larsson, Tord
    Örebro universitet, Institutionen för teknik.
    Kylning av förarhytt i eldrivna truckar: en förstudie2007Rapport (Annet vitenskapelig)
    Abstract [sv]

    Denna rapport är resultatet av en sk tekniklösning för att kyla förarhytten i eldrivna truckar. Uppdraget är utfört med medel från Innovationsbron Väst AB via Mobab AB till institutionen för teknik vid Örebro universitet.

    Att söka en tekniklösning innebär att genom en förstudie försöka finna en möjlig kylprocess som inte drar så mycket elektrisk energi och som Mobab AB sedan skall utveckla vidare till kommersiell produkt.

    En beräkning av kyllasten för en tänkt truckhytt placerad i Kalmar respektive Bologna redovisas. En enkel värmebalans för en truckhytt har gjorts för ett driftfall i varje ort. Teoretiskt dimensionerade luftflöden med hänsyn till klimat och luftkvalitet har tagits fram. Ett tiotal olika kylprocesser har redovisats och diskuterats.

    Rapporten förordnar frånluftvärmeväxlad indirekt evaporativ fuktning/kylning som tekniklösning. Ett flödesschema på kylprocessen redovisas för att beskriva tekniklösningen.

  • 8.
    Larsson, Tord
    Örebro universitet, Institutionen för teknik.
    Mätning av temperaturverkningsgraden för värmeväxlare i luftbehandlingssystem2005Inngår i: Kvalitetsstyrd förvaltning, energi - miljö, Göteborg: Lokalförsörjningsförvaltningen, LFF, Göteborg , 2005, , s. 12Kapittel i bok, del av antologi (Annet vitenskapelig)
  • 9.
    Larsson, Tord
    Örebro universitet, Institutionen för teknik.
    Mätosäkerhet vid mätning av gaskällor och gassänkor i ventilerade utrymmen2004Rapport (Annet vitenskapelig)
    Abstract [sv]

    A common way to measure the sink or source of gases in ventilated rooms is to use one measuring instrument and one control valve. The control valve, which is operated by a computer, obtains samples of gas from exhaust and supply air. The measurements obtained are then analysed using various difference methods. The largest uncertainty occurs in the gas measurement irrespective of which of the gases is measured in this case, carbon dioxide, formaldehyde (FAD) and total volatile organic compounds (TVOC). Carbon dioxide is measured by the NDIR-method and both FAD and TVOC are measured by the PAS-method. If the standard uncertainty for the measurement of carbon dioxide is reduced from 4 ppm to 0,0002 pm, the influence from the airflow rate is affected from 0 up to 10 % of the uncertainty for the measured specified carbon dioxide flow rate. If the air climate in exhaust and supply air is measured, it is possible to find a slight influence from the measurement of the airflow rate. Two temperature sensors and two moisture sensors measure the climate.

  • 10.
    Larsson, Tord
    Örebro universitet, Institutionen för teknik.
    Några inomhusväxters förmåga att påverka luftkvaliteten2004Doktoravhandling, monografi (Annet vitenskapelig)
    Abstract [en]

    People spend more than 80 % of the day indoors and are mostly exposed to contaminated air. Some authors suggest that indoor plants are good as indoor air cleaners. Authors have studied the sink effect of indoor plants in unventilated closed systems. Unfortunately, the results from these studies cannot be applied in the design of HVAC-systems because they do not contain proper parameters, such as air change rate.

    In this study the sink and source effects of three different indoor plants have been investigated for carbon dioxide (CO2), formaldehyde (FAD), and total volatile organic compound (TVOC). The measurements have been made in two different climate chambers, a climate box of 0.56 m3 and a clean room of 19.6 m3. Both inlet and outlet air concentrations of CO2, FAD, TVOC, and content of water were measured. In addition the light intensity levels, lux and photoactive radiation (Par), were measured. The three following families of indoor plants have been tested: Epipremnum, Schefflera and Spathiphyllum.

    A new method of measuring leaf area is described. The plant’s leaf area has been measured with a photo scanner for a selected number of leaves and the relationship between the characteristic length and the area has been calculated using regression analysis. The characteristic length was measured for all leaves of the plants and used to calculate the total leaf area.

    A special mixture, containing six ordinary volatile organic compounds normally found in indoor air, was used to simulate TVOC. The concentration of TVOC was measured using photo acoustic infrared spectroscopy (PAS).

    Both single step and double step forward finite difference methods have been used for the calculations of the indoor concentration dilution of contaminants. The latter method is preferred when using one single instrument and a switching valve for monitoring the concentration and gas flow from both the inlet and the outlet of the chamber. In the calculations the influence of the chamber has been taken into consideration.

    The results show that for the studied plants, the sink effect of CO2 is -0.05 to -0.1 g CO2 m-2 h-1 at day-time (500 lx) and that the source strength at night-time is 0.1 g CO2 m-2 h-1 when the inlet concentration of CO2 air is 400 ppm. If the inlet air concentration is 1500 ppm CO2 the sink effect is larger, ranging from -2 to -6 g CO2 m-2 h-1. The sink effect of FAD is in the range of -0.3 to -1 mg FAD m-2 h-1 (at the background concentration of 0.3 mg FAD m-3), and the sink effect of TVOCpas is -0.25 to - 0.5 mg TVOCpas m-2 h-1 (at the background concentration of 1-2 mg TVOCpas m-3). The source strength of water is in the range of 0.005-0.01 g H2O m-2 h-1 (at nighttime) and 0.008 to 0.01 g H2O m-2 h-1 (at day-time).

  • 11.
    Larsson, Tord
    Örebro universitet, Institutionen för teknik.
    Sammanställning av mediaförbruknings-situationen för Örebro universitet 19981999Inngår i: Miljöutredningen, Örebro universitet, 1999Kapittel i bok, del av antologi (Annet (populærvitenskap, debatt, mm))
  • 12.
    Larsson, Tord
    Örebro universitet, Institutionen för teknik.
    Standardiserade utskrifter för bedömning av skrivares och kopiatorers avgivning av flyktiga organiska ämnen och partiklar2006Rapport (Annet vitenskapelig)
    Abstract [sv]

    Standardising of out printings to estimate printers and copiers emitting of volatile organic compounds (VOC) and particles. This report describes a proposal standard for printing and coping to measurement TVOC, VOC, other organic compounds, particles and contamination from printer and copier machine. The proposal standard gives information about:

    The way that all information gives to repeat similar measurement and get them comparable. In appendix the printing is showed. A test showed that an ink-jet printer produce 0.72 mg TVOCPAS A4-1 and 2100+-215 particles (0.1-0.3 "my"m) A4-1 when this out printing standard is used.

  • 13.
    Larsson, Tord
    Örebro universitet, Akademin för naturvetenskap och teknik.
    Validering av partikelavskiljning och produktförändring av en AerosolTrapTM2010Rapport (Annet vitenskapelig)
    Abstract [en]

    Validation and design of a particle trap. The purpose of the project is to measure  a product's (AerosolTrap®) technical properties and to calculate the product with the computer program Ansys workbench. Later on ProE was used for solid modeling, Ansys (Finita element generation) together with Ansys Fluent (flow's - and particle track modeling) in order to evaluate the measured model. In the study  it is shown that these program’s and multivariat analysis can be used to create a product capable of handling for using smaller particles with higher density.The evaluation shows that the measurement properties of technical corresponds well with the computer model concerning airflow and 3-7 mm cell plastic bulbs with density of 32.5 kg m-3. One robust calculation process has also been created.The simulation with multivariat analysis is preformed and a new product, a model, has been created with Ansys workbench. The product properties as airflow, particle density and size can, be controlled with multivariat analysis.

    Fulltekst (pdf)
    FULLTEXT01
  • 14.
    Larsson, Tord
    Örebro universitet, Institutionen för teknik.
    Växter är inga bra luftrenare2006Inngår i: Inomhusklimat Örebro 2006: konferens i Örebro 14-15 mars 2006, Örebro: Yrkes- och miljömedicinska kliniken, Universitetssjukhuset Örebro , 2006Konferansepaper (Annet vitenskapelig)
    Abstract [sv]

    I veckopress påstås ofta att växter är bra luftrenare. De mätningarna som det då hänvisas till var utförda i icke ventilerade utrymme och i redovisningen anges inte storleksordningen för växterna. Denna artikel visar att växter inte är några bra luftrenare och slutsatsen är underbyggd av ett fyra årigt forskningsprojekt vid Chalmers tekniska högskola och vid Örebro universitet. Försöken som här redovisas är utförda i en ventilerat mätbox och i ett ventilerat renrum.

    För att kvantitativt kunna bestämma en krukväxts egenskap att rena luft har begreppet specifikt massflöde gas används. Det är ett mått på hur mycket gas en växt av en viss storlek tar upp eller avger per tidsenhet. Det innebär att krukväxten som källa eller sänka av en gas av en gas i ett rum är uppmätt som milligram gas per bladarea och per timme. För att kvantifiera växtens storlek används begreppet bladarea. För att mäta bladarean skapas först ett samband mellan en karakteristisk längd på bladet och bladets area. Sedan mäts samtliga blads karakteristisk längd och krukväxtens totala bladarea beräknas. För att mäta och beräkna massflödet av en viss gas har traditionella mätmetoder används, vilket innebär att gaskoncentrationen mäts i tilluften och frånluften i mätkamrarna och därur beräkna rummet sänka av aktuell mätt gas.

    De gaser som är uppmäta är koldioxid, formaldehyd och en speciell blandning av vanligt förekommande flyktiga organiska ämnen, Stridhs-blandning. Krukväxterna tar inomhus i normal belysning på något sätt upp dessa gaser i mycket små mängder. Växterna avger vattenånga och på natten även koldioxid.

    Mängden upptag är så liten att de inte nämnvärt kan påverka luftkvaliteten i kontorsrum eller bostadsrum.

  • 15.
    Larsson, Tord
    Örebro universitet, Institutionen för teknik.
    Växter är inga bra luftrenare2005Inngår i: VVS Teknik & Installation, VVS forum, ISSN 0346-4644Artikkel i tidsskrift (Annet (populærvitenskap, debatt, mm))
  • 16.
    Larsson, Tord
    et al.
    Örebro universitet, Institutionen för teknik.
    Brorsson, M.
    Byggteknik.
    Ellervik, A.
    Byggteknik.
    Nygren, Tobias
    Byggteknik.
    Industrialiserat byggande: en granskning av några olika metoder2004Rapport (Annet vitenskapelig)
    Abstract [sv]

    Det finns idag (2004) ett flertal exempel på prefabbyggen med lätta stommar. Byggelementen är antingen volymelement eller planelement eller kombinationer som på byggplatsen monteras ihop tillsammans med den för husets funktion viktiga infrastrukturen såsom grund, trapphus, installationsstammar och apparatrum. Tre olika koncept har undersökts nämligen Move In®, Bo Klok och B4. Move In är ett volymelementkoncept med moduler som innefattar stjärnhus, punkthus, lamellhus och vinkelhus. Bo Klok är ett volymelementkoncept med moduler och byggs som vinkelhus medan B4 är planelementkoncept för olika typer av flerbostadshus. Det är möjligt att bygga upp till fyra våningar med Move In och B4, medan Bo Klok konceptet är ett två våningskoncept. Vid byggprojekt med byggelement med lätta stommar är det viktigt att så tidigt som möjligt starta processen att planera för prefabbygge. Denna start skall ske redan i programstadiet. Både projekterings- och produktionsskedet är annorlunda än vid traditionella platsbyggda projekt. Särskilt elementens storlekt vid transporten styr storleksmått på planlösningen i husen. Samordning mellan de delar som kommer att bli platsbyggda infrastrukturen är viktig. I rapporten redovisas synpunkter från arkitekter, byggtekniker, statiker och installationstekniker, från modulproduktionen och från förvaltare. Vidare redovisas för ett tiotal materialval och Move Ins motiv till varför de valt just detta material. För samma material ger sedan någon tillverkare och förvaltare sin syn på dessa material. Detta gäller för fönster, våtrumsskivor, träullskivor, klinker, linoleummatta, utomhus - och inomhusfärg, trästomme, grundläggning och köksluckor. Motivet till Move Ins val är att lösningarna som givet dessa materialval ofta är grundade på underhålls- och miljöaspekter. Rapporten är till viss del en sammanfattning och en analys av två examensarbeten, referens (Nygren, 2003)[15] och (Ellervik och Brorsson, 2004) [17].

  • 17.
    Larsson, Tord
    et al.
    Örebro universitet, Institutionen för naturvetenskap och teknik.
    Kjellander, Johan
    Örebro universitet, Institutionen för naturvetenskap och teknik.
    Överstam, Henrik
    Örebro universitet, Institutionen för naturvetenskap och teknik.
    “Aerosoltrap” a new device for inertial dust separation: CFD simulations with experimental validation2013Inngår i: Particulate Science and Technology, ISSN 0272-6351, E-ISSN 1548-0046, Vol. 31, nr 3, s. 221-225Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Inertial separation of dust from air/gas streams using settling- or baffle chambers is simple and cost effective. In order to increase the effectiveness of a single chamber AerosolTrap has been developed. This new device uses 4 chambers in series, stacked on top of each other. The aim of the present study is to examine the performance of AerosolTrap and investigate if CFD simulations can be used as a tool to optimize its geometry. Simulations and validating laboratory experiments have been performed using different flows and different mix of particles. The paper describes the methodology used and presents results that show that CFD simulations predict the general characteristics of the AerosolTrap well but underestimates the separation coefficient slightly.

  • 18.
    Larsson, Tord
    et al.
    Örebro universitet, Institutionen för teknik.
    Pettersson, Ulla
    Örebro universitet, Institutionen för teknik.
    Översiktlig verksamhetsbeskrivning av KY-utbildningen vid högskolan1998Rapport (Annet vitenskapelig)
1 - 18 of 18
RefereraExporteraLink til resultatlisten
Permanent link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf