Impact of iterative reconstruction on image quality of low-dose CT of the lumbar spine
Örebro universitet, Institutionen för medicinska vetenskaper. Region Örebro län. Department of Radiology, Örebro University Hospital, Örebro, Sweden.ORCID-id: 0000-0003-0137-9991
Örebro universitet, Institutionen för medicinska vetenskaper. Region Örebro län. Department of Radiology, Örebro University Hospital, Örebro, Sweden; Department of Medical Imaging and Physiology, Skåne University Hospital, Lund University, Lund, Sweden.ORCID-id: 0000-0003-0529-7723
Örebro universitet, Institutionen för medicinska vetenskaper. Region Örebro län. Department of Medical Physics, Örebro University Hospital, Örebro, Sweden.
Örebro universitet, Institutionen för medicinska vetenskaper. Region Örebro län. Department of Radiology, Örebro University Hospital, Örebro, Sweden.ORCID-id: 0000-0002-1346-1450
Vise andre og tillknytning
2017 (engelsk)Inngår i: Acta Radiologica, ISSN 0284-1851, E-ISSN 1600-0455, Vol. 58, nr 6, s. 702-709Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Background: Iterative reconstruction (IR) is a recent reconstruction algorithm for computed tomography (CT) that can be used instead of the standard algorithm, filtered back projection (FBP), to reduce radiation dose and/or improve image quality.

Purpose: To evaluate and compare the image quality of low-dose CT of the lumbar spine reconstructed with IR to conventional FBP, without further reduction of radiation dose.

Material and Methods: Low-dose CT on 55 patients was performed on a Siemens scanner using 120 kV tube voltage, 30 reference mAs, and automatic dose modulation. From raw CT data, lumbar spine CT images were reconstructed with a medium filter (B41f) using FBP and four levels of IR (levels 2-5). Five reviewers scored all images on seven image quality criteria according to the European guidelines on quality criteria for CT, using a five-grade scale. A side-by-side comparison was also performed.

Results: There was significant improvement in image quality for IR (levels 2-4) compared to FBP. According to visual grading regression, odds ratios of all criteria with 95% confidence intervals for IR2, IR3, IR4, and IR5 were: 1.59 (1.39-1.83), 1.74 (1.51-1.99), 1.68 (1.46-1.93), and 1.08 (0.94-1.23), respectively. In the side-by-side comparison of all reconstructions, images with IR (levels 2-4) received the highest scores. The mean overall CTDIvol was 1.70 mGy (SD 0.46; range, 1.01-3.83 mGy). Image noise decreased in a linear fashion with increased strength of IR.

Conclusion: Iterative reconstruction at levels 2, 3, and 4 improves image quality of low-dose CT of the lumbar spine compared to FPB.

sted, utgiver, år, opplag, sider
London: Sage Publications, 2017. Vol. 58, nr 6, s. 702-709
Emneord [en]
X-ray computed tomography (CT), image manipulation/reconstruction, lumbar vertebrae, radiation dosage, spine
HSV kategori
Identifikatorer
URN: urn:nbn:se:oru:diva-57646DOI: 10.1177/0284185116669870ISI: 000399995700011PubMedID: 28157395Scopus ID: 2-s2.0-85019010032OAI: oai:DiVA.org:oru-57646DiVA, id: diva2:1095142
Tilgjengelig fra: 2017-05-12 Laget: 2017-05-12 Sist oppdatert: 2024-03-06bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMedScopus

Person

Alshamari, MuhammedGeijer, MatsNorrman, EvaLidén, MatsKrauss, WolfgangJendeberg, JohanGeijer, Håkan

Søk i DiVA

Av forfatter/redaktør
Alshamari, MuhammedGeijer, MatsNorrman, EvaLidén, MatsKrauss, WolfgangJendeberg, JohanGeijer, Håkan
Av organisasjonen
I samme tidsskrift
Acta Radiologica

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 735 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf