To Örebro University

oru.seÖrebro universitets publikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Effective dose in low-dose CT compared with radiography for templating of total hip arthroplasty
Region Örebro län. Örebro universitet, Institutionen för medicinska vetenskaper. Department of Radiology, Örebro University Hospital, Örebro, Sweden; Department of Clinical Sciences, Lund University, Lund, Sweden.ORCID-id: 0000-0003-0529-7723
Department of Clinical Sciences, Lund University, Lund, Sweden.
Department of Clinical Sciences, Lund University, Lund, Sweden; Department of Radiation Physics, Skåne University Hospital, Lund, Sweden.
Department of Clinical Sciences, Lund University, Lund, Sweden; Department of Orthopedics, Skåne University Hospital, Lund, Sweden.
2017 (engelsk)Inngår i: Acta Radiologica, ISSN 0284-1851, E-ISSN 1600-0455, Vol. 58, nr 10, s. 1276-1282Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Background: Recently, total hip arthroplasty (THA) has come to focus on restoration of individual anatomy including femoral neck anteversion and global offset (femoral and acetabular offset). Three-dimensional (3D) computed tomography (CT) data could provide a better basis for preoperative templating. The use of CT has been hampered by high radiation dose.

Purpose: To evaluate the effective dose used in pelvis and hip CT for THA templating.

Material and Methods: CT data from two clinical trials of THA were evaluated for CT scan length and volume CT dose index (CTDIvol). The effective doses from hip-knee-ankle CT and pelvis and hip radiography were compared. Conversion factors for effective dose for radiography were calculated using the PCXMC software.

Results: A reduced dose CT protocol for pelvis imaging gave a substantial dose reduction compared with standard CT, while maintaining sufficient image quality. Between the two clinical trials there was a significant reduction in effective CT dose corresponding to changes in the CT protocol (P<0.01). The CT dose for the latter group was similar to, but nevertheless significantly higher than for, radiography (P<0.01). However, in the latter group the theoretical minimum dose for CT, using the minimum scan length required by the templating software, was equal to the dose from radiography.

Conclusion: Although the CT dose remained higher than for radiography, potential reductions in scan length could reduce the dose further so that CTwould have a comparable level of risk to radiography with the added benefit of 3D templating.

sted, utgiver, år, opplag, sider
London, United Kingdom: Sage Publications, 2017. Vol. 58, nr 10, s. 1276-1282
Emneord [en]
X-ray computed tomography (CT), radiography, hip arthroplasty, radiation dose
HSV kategori
Identifikatorer
URN: urn:nbn:se:oru:diva-61035DOI: 10.1177/0284185117693462ISI: 000408644400016PubMedID: 28347158Scopus ID: 2-s2.0-85027459537OAI: oai:DiVA.org:oru-61035DiVA, id: diva2:1142351
Tilgjengelig fra: 2017-09-19 Laget: 2017-09-19 Sist oppdatert: 2026-01-15bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMedScopus

Person

Geijer, Mats

Søk i DiVA

Av forfatter/redaktør
Geijer, Mats
Av organisasjonen
I samme tidsskrift
Acta Radiologica

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 283 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf