To Örebro University

oru.seÖrebro universitets publikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Contact allergy to oxidized geraniol among Swedish dermatitis patients: A multicentre study by the Swedish Contact Dermatitis Research Group
Department of Dermatology, Sahlgrenska Academy at University of Gothenburg, Gothenburg, Sweden.
Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden.
Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden.
Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden.
Vise andre og tillknytning
2018 (engelsk)Inngår i: Contact Dermatitis, ISSN 0105-1873, E-ISSN 1600-0536, Vol. 79, nr 4, s. 232-238Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

BACKGROUND: Geraniol is a widely used fragrance terpene, and is included in fragrance mix I. Geraniol is prone to autoxidation, forming the skin sensitizers geranial, neral, and geraniol-7-hydroperoxide. Oxidized geraniol has previously been patch tested in 1 clinic, giving 1% to 4.6% positive reactions in consecutive patients when tested at 2% to 11%.

AIM: To compare test reactions to pure and oxidized geraniol, to compare 2 different test concentrations of oxidized geraniol and to investigate the pattern of concomitant reactions to fragrance markers of the baseline series in a multicentre setting.

METHODS: One thousand four hundred and seventy-six consecutive patients referred for patch testing were patch tested with geraniol 6% pet. and oxidized geraniol 6% and 11% pet.

RESULTS: Pure geraniol 6% pet., oxidized geraniol 6% pet. and oxidized geraniol 11% pet. gave 1%, 3% and 8% positive patch test reactions and 0.7%, 3% and 5% doubtful reactions, respectively. Approximately 50% of the patients with doubtful reactions to oxidized geraniol 6% pet. had positive reactions to oxidized geraniol 11% pet.

CONCLUSIONS: Oxidized geraniol 11% pet. provides better detection than oxidized geraniol 6% pet. As most patients reacted only to oxidized geraniol, it is important to explore further whether oxidized geraniol should be included in a baseline patch test series.

sted, utgiver, år, opplag, sider
Blackwell Publishing, 2018. Vol. 79, nr 4, s. 232-238
Emneord [en]
allergic contact dermatitis, autoxidation, fragrance contact allergy, fragrance mix I, geraniol, patch testing, terpenes
HSV kategori
Identifikatorer
URN: urn:nbn:se:oru:diva-67512DOI: 10.1111/cod.13047ISI: 000443805100006PubMedID: 29926925Scopus ID: 2-s2.0-85052815523OAI: oai:DiVA.org:oru-67512DiVA, id: diva2:1224036
Merknad

Funding Agency:

Edvard Welanders Stiftelse 

Tilgjengelig fra: 2018-06-26 Laget: 2018-06-26 Sist oppdatert: 2018-09-25bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMedScopus

Person

Lindberg, Magnus

Søk i DiVA

Av forfatter/redaktør
Lindberg, Magnus
Av organisasjonen
I samme tidsskrift
Contact Dermatitis

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 145 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf