To Örebro University

oru.seÖrebro universitets publikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Accuracy and reliability of continuous glucose monitoring in individuals with type 1 diabetes during recreational diving
Gothenburg Pediatric Growth Research Center, Department of Pediatrics, Institute for the Health of Women and Children, The Sahlgrenska Academy at Gothenburg University, Gothenburg, Sweden.
Swedish Sports Diving Federation, Farsta, Sweden.
Endocrine and Diabetes Center, Karlstad Hospital, Karlstad, Sweden; Faculty of Health Sciences, Örebro University Hospital, Örebro, Sweden.ORCID-id: 0000-0003-1025-1682
2009 (engelsk)Inngår i: Diabetes Technology & Therapeutics, ISSN 1520-9156, E-ISSN 1557-8593, Vol. 11, nr 8, s. 493-497Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

BACKGROUND: This study evaluated the accuracy and function of the Continuous Glucose Monitoring System (CGMS, Minneapolis, MN) during recreational scuba diving in individuals with type 1 diabetes.

METHODS: Twenty-four adults, 12 with type 1 diabetes and 12 healthy controls, were studied during five recreational scuba dives performed on three consecutive days. All the participants used the CGMS on all the days and during all the dives. Comparisons were made between plasma glucose at specific time intervals and the CGMS.

RESULTS: The recording by the CGMS was robust, with few sensor problems. The mean sensor survival time was >48 h. Eighty-five percent of the individuals used one sensor during the entire length of the trial. The overall mean absolute difference (MAD) within the group with diabetes was 14.4 +/- 6%, and the corresponding daily figures were 23.2 +/- 19.3% on day 1, 11.6 +/- 4.5% on day 2, and 11.2 +/- 5.7% on day 3. A significant improvement regarding MAD when day 1 was compared with day 2 and 3 (P < 0.05). With a limit set at 70 mg/dL, hypoglycemia pre- and post-dive was detected with a positive predictive value of 0.39, negative predictive value of 0.98, sensitivity of 0.64, and specificity of 0.94.

CONCLUSIONS: We demonstrate that the CGMS was used with accuracy in such difficult conditions as scuba diving and provided robust information on glucose variations.

sted, utgiver, år, opplag, sider
Mary Ann Liebert, 2009. Vol. 11, nr 8, s. 493-497
HSV kategori
Identifikatorer
URN: urn:nbn:se:oru:diva-74513DOI: 10.1089/dia.2009.0017ISI: 000269170100005PubMedID: 19698062Scopus ID: 2-s2.0-70349472622OAI: oai:DiVA.org:oru-74513DiVA, id: diva2:1319140
Merknad

Research funders:

Aidera

Medtronic

Novo Nordisk

Center of Clinical Research at the County Council of Värmland

Tilgjengelig fra: 2019-05-29 Laget: 2019-05-29 Sist oppdatert: 2019-06-12bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMedScopus

Person

Jendle, Johan

Søk i DiVA

Av forfatter/redaktør
Jendle, Johan
I samme tidsskrift
Diabetes Technology & Therapeutics

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 481 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf