To Örebro University

oru.seÖrebro universitets publikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Produktutveckling för reducerad ljudnivå på luftbehandlingsaggregat
Örebro universitet, Institutionen för naturvetenskap och teknik.
2021 (svensk)Independent thesis Basic level (professional degree), 10 poäng / 15 hpOppgave
Abstract [sv]

Examensarbetet har genomförts på ett ventilationsföretag. Företaget tillverkar bland annat luftbehandlingsaggregat vilket denna rapport behandlar. Examensarbetets syfte var att se om en reducering av mekaniska vibrationer i aggregatets chassi ger en minskning av den totala ljudnivån. Vibrationer uppstår i fläktarna, antingen från det producerade luftflödet eller från mekaniska vibrationer då fläkten är direkt monterad i chassit. För att minska de mekaniska vibrationerna i chassit konstruerades tre prototyper där gummi-distanser isolerade fläkten från chassit. Prototyperna testades genom vibrationslaborationer där vibrationer mättes i enheten m/s2 samt över ett frekvensspektrum som ett Fast Fourier Transform diagram (FFT-diagram). Avslutningsvis genomfördes en ljudmätning på den prototyp där vibrationer reducerats mest. Vibrationerna i chassit reducerades. Den totala ljudnivån från aggregatet reducerades. För fortsatt arbete rekommenderas laborationer med andra hårdheter på gummi-distanserna.  

Abstract [en]

The bachelor thesis has been carried out at a ventilation company. The company manufactures, among other things, air handling units, which this report deals with. The purpose of the thesis was to see if a reduction of mechanical vibrations in the unit's chassis reduces the overall noise level. Vibrations occur in the fans, either from the produced air flow or from mechanical vibrations when the fan is mounted directly in the chassis. To reduce the mechanical vibrations in the chassis, three prototypes were constructed in which rubber bodies insulated the fan from the chassis. The prototypes were tested through vibration laboratories where vibrations were measured in the unit m/s2 and over a frequency spectrum as a Fast Fourier Transform diagram (FFT-diagram). Finally, a sound measurement was performed on the prototype where the largest reduction in vibrations occurred. The vibrations in the chassis were reduced. The total noise level from the unit was reduced. For further work, laboratory work with other hardnesses on the rubber distances is recommended. 

sted, utgiver, år, opplag, sider
2021. , s. 24
Emneord [en]
Product development, Vibration measurement, Sound measurement, Mechanical vibrations
Emneord [sv]
Produktutveckling, Vibrationsmätning, Ljudmätning, Mekaniska vibrationer
HSV kategori
Identifikatorer
URN: urn:nbn:se:oru:diva-92557OAI: oai:DiVA.org:oru-92557DiVA, id: diva2:1571292
Fag / kurs
Mechanical Engineering
Examiner
Tilgjengelig fra: 2021-06-22 Laget: 2021-06-22 Sist oppdatert: 2021-06-22bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric

urn-nbn
Totalt: 71 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf