To Örebro University

oru.seÖrebro universitets publikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
High levels of hemolysis do not affect measurement of PAPP-A, β-HCG and TRAb on BRAHMS KRYPTOR compact plus
Örebro universitet, Institutionen för medicinska vetenskaper. Region Örebro län. Department of Clinical Chemistry, Division of Laboratory Medicine.ORCID-id: 0000-0001-8458-6448
Örebro universitet, Institutionen för medicinska vetenskaper. Region Örebro län. Department of Clinical Chemistry, Division of Laboratory Medicine.ORCID-id: 0009-0003-1728-8661
Örebro universitet, Institutionen för medicinska vetenskaper. Region Örebro län. Department of Clinical Chemistry, Division of Laboratory Medicine.ORCID-id: 0000-0002-4256-6008
2023 (engelsk)Inngår i: Scandinavian Journal of Clinical and Laboratory Investigation, ISSN 0036-5513, E-ISSN 1502-7686, Vol. 83, nr 6, s. 367-370Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

To assess the impact of high levels of hemolysis on the laboratory results for free β-hCG, PAPP-A, and TRAb performed on the B·R·A·H·M·S KRYPTOR Compact PLUS. Adapted from the CLSI guidelines EP07-A2, paired difference testing was performed on serum samples from the routine laboratory workflow. Three sample pools for each assessed analyte was prepared and subjected to increased levels of added hemolysate. For β-hCG and PAPP-A, the relative difference in the measured analyte concentration between the sample with 0 g/L added Hb and the samples with increasing free Hb concentrations (up to 6 g/L), was well below the pre-set acceptance criterion of 10% at all levels. The TRAb results showed greater variation than the other analytes, likely a consequence of imprecision rather than hemolysis. Hemolysis has a negligible effect on the analysis results of free beta-hCG, PAPP-A and TRAb measured on the B·R·A·H·M·S KRYPTOR Compact PLUS.

sted, utgiver, år, opplag, sider
Taylor & Francis, 2023. Vol. 83, nr 6, s. 367-370
Emneord [en]
Chorionic gonadotropin, TSH receptor antibody, beta subunit, fluoroimmunoassay, hemolysis, human, pregnancy-associated plasma protein-A
HSV kategori
Identifikatorer
URN: urn:nbn:se:oru:diva-107472DOI: 10.1080/00365513.2023.2233886ISI: 001029248700001PubMedID: 37458499Scopus ID: 2-s2.0-85165243868OAI: oai:DiVA.org:oru-107472DiVA, id: diva2:1786631
Tilgjengelig fra: 2023-08-09 Laget: 2023-08-09 Sist oppdatert: 2023-12-08bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMedScopus

Person

Pettersson-Pablo, PaulAneskans, CeciliaVink, Martin

Søk i DiVA

Av forfatter/redaktør
Pettersson-Pablo, PaulAneskans, CeciliaVink, Martin
Av organisasjonen
I samme tidsskrift
Scandinavian Journal of Clinical and Laboratory Investigation

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 75 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf