Automated oxygen titration at home for patients with COPD - a pilot study
Örebro universitet, Institutionen för medicinska vetenskaper. Hvidovre University Hospital, Hvidovre, Denmark.ORCID-id: 0000-0002-1184-9451
Hvidovre University Hospital, Hvidovre, Denmark.
Aalborg University Hospital, Aalborg, Denmark.
Bispebjerg Hospital, Copenhagen, Denmark; Copenhagen University, Copenhagen, Denmark.
Vise andre og tillknytning
2023 (engelsk)Inngår i: European Respiratory Journal, ISSN 0903-1936, E-ISSN 1399-3003, Vol. 62, nr Suppl. 67, artikkel-id PA1040Artikkel i tidsskrift, Meeting abstract (Annet vitenskapelig) Published
Abstract [en]

Introduction: Automated oxygen titration (AutOx) is a new technology which could give patients with chronic respiratory failure the opportunity of personalized oxygen treatment. AutOx has been tested in a safe environment but never in a real life setting for several days in the patient's home.

Aim: To investigate the setup of automated oxygen in the home of patients with chronic respiratory failure in a pilot study.

Methods: A new device, O2matic HOT, was connected to a high-flow concentrator which could provide for up to 10 l/min. Patients wore a Nonin WristOx pulse oximeter, connected via bluetooth to the O2matic HOT. In a closed-loop circuit oxygen flow was titrated based on oxygen saturation (SpO2). Patients were encouraged to wear the pulse oximeter as much as possible, also during activity. Data was sent to a cloud solution.

Results: Two patients tested the setup for each 4 days. Pulse oximeter signal was achieved for 78.3 to 78.9 % of the time, with 272,399 paired observations of SpO2 and oxygen flow for patient 1 and 262,568 observations for patient 2. SpO2 was in target interval (90-94 %) in 94.8 % of the time for patient 1 and 84.7 % of the time for patient 2. Oxygen flow was median 1.3 l/min (2.5-97.5 % percentile: 1.0-5.9 l/min) for patient 1 and median 0.6 l/min (2.5-97.5 % percentile: 0.5-6.7 l/min) for patient 2.

Discussion: It is possible to titrate oxygen flow in a home setting and achieve almost perfect control of SpO2, but it requires major adjustments in oxygen flow. The clinical importance of controlling SpO2 is not clear, but dyspnea and endurance has been shown to improve with titrated oxygen. Further studies will be needed to examine the feasibility of automated oxygen titration at home.

sted, utgiver, år, opplag, sider
European Respiratory Society , 2023. Vol. 62, nr Suppl. 67, artikkel-id PA1040
HSV kategori
Identifikatorer
URN: urn:nbn:se:oru:diva-110853DOI: 10.1183/13993003.congress-2023.PA1040ISI: 001109120502199OAI: oai:DiVA.org:oru-110853DiVA, id: diva2:1830886
Konferanse
ERS International Congress 2023, Milan, Italy, September 9-13, 2023
Tilgjengelig fra: 2024-01-24 Laget: 2024-01-24 Sist oppdatert: 2025-04-30bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Person

Kofod, Linette MarieWesterdahl, Elisabeth

Søk i DiVA

Av forfatter/redaktør
Kofod, Linette MarieWesterdahl, Elisabeth
Av organisasjonen
I samme tidsskrift
European Respiratory Journal

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 64 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf