To Örebro University

oru.seÖrebro universitets publikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Characteristics and health risks of the inhalable fraction of metal additive manufacturing powders
Örebro universitet, Institutionen för naturvetenskap och teknik. School of Medical Sciences Faculty of Medicine and Health, Örebro University, Örebro, Sweden; Inflammatory Response and Infection Susceptibility Centre (iRiSC), Faculty of Medicine and Health, Örebro University, Örebro, Sweden. (Man-Technology-Environment research center (MTM))ORCID-id: 0000-0002-2403-7989
KTH Royal Institute of Technology, Division of Surface and Corrosion Science, Stockholm, Sweden.
Institute of Environmental Medicine, Karolinska Institute, Stockholm, Sweden.
Swerim, Kista, Sweden.
Vise andre og tillknytning
2024 (engelsk)Inngår i: Nano Select, E-ISSN 2688-4011, Vol. 5, nr 4, artikkel-id 2300188Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Metal additive manufacturing (AM) is gaining traction but raises worker health concerns due to micron-sized powders, including fine inhalable particles. This study explored particle and surface characteristics, electrochemical properties, metal release in artificial lysosomal fluid (ALF), and potential toxicity of virgin and sieved virgin Fe-based powders, stainless steel (316L), Fe, and two tooling steels. Virgin particles ranged in size from 1 to 100μm, while sieved particles were within the respirable size range (<5–10μm). Surface oxide composition differed from bulk composition. The Fe powder showed low corrosion resistance and high metal release due to a lack of protective surface oxide. Sieved particles of 316L, Fe, and one tooling steel released more metals into ALF than virgin particles, with the opposite was observed for the other tooling steel. Sieved particles had no notable impact on cell viability or micronuclei formation in human bronchial epithelial cells. Inflammatory response in human macrophages was generally low, except for the Fe powder and one tooling steel, which induced increased interleukin-8 (IL-8/CXCL-8) and monocyte chemoattractant protein-1 (MCP-1/CCL-2) secretion. This study underscores distinctions between virgin and sieved Fe-based powders and suggests relatively low acute toxicity.

sted, utgiver, år, opplag, sider
Wiley-VCH Verlagsgesellschaft, 2024. Vol. 5, nr 4, artikkel-id 2300188
Emneord [en]
AM manufacturing, exposure, genotoxicity, inflammation, inhalable metallic powders, particle dissolution
HSV kategori
Forskningsprogram
Biologi
Identifikatorer
URN: urn:nbn:se:oru:diva-112113DOI: 10.1002/nano.202300188ISI: 001186503300001OAI: oai:DiVA.org:oru-112113DiVA, id: diva2:1842620
Forskningsfinansiär
Vinnova, 2021‐03968Knowledge Foundation, 20190107Knowledge Foundation, 20200017Knowledge Foundation, 20220122Tilgjengelig fra: 2024-03-05 Laget: 2024-03-05 Sist oppdatert: 2025-02-01bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Person

Alijagic, AndiSärndahl, Eva

Søk i DiVA

Av forfatter/redaktør
Alijagic, AndiSärndahl, EvaOdnevall, Inger
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 266 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf