Decontamination and Surface Analysis of PFAS-Contaminated Fire Suppression System Pipes: Effects of Cleaning Agents and Temperature
Department of Aquatic Sciences and Assessment, Swedish University of Agricultural Sciences, Uppsala 75651, Sweden.
Surrey Ion Beam Centre, University of Surrey, Guildford, Surrey GU2 7XH, U.K.
Department of Molecular Sciences, Swedish University of Agricultural Sciences, Uppsala 75651, Sweden.
Örebro universitet, Institutionen för naturvetenskap och teknik. (SMTM Research Centre)ORCID-id: 0000-0001-6800-5658
Vise andre og tillknytning
2025 (engelsk)Inngår i: Environmental Science and Technology, ISSN 0013-936X, E-ISSN 1520-5851, Vol. 59, nr 4, s. 2222-2232Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Per- and polyfluoroalkyl substances (PFAS)-containing firefighting foam have been used in stationary fire suppression systems for several decades. However, there is a lack of research on how to decontaminate PFAS-contaminated infrastructure and evaluate treatment efficiency. This study assessed the removal of PFAS from stainless steel pipe surfaces using different cleaning agents (tap water, methanol, and aqueous solutions containing 10 and 20 wt % of butyl carbitol (BC)) at different temperatures (20 °C, 40 °C, and 70 °C). The content of the remaining fluorine (F)-containing compounds on the pipe surfaces was evaluated for the first time using time-of-flight elastic recoil detection (ToF-ERD). The results showed that a 20% BC aqueous solution heated to 70 °C removed up to 40 μg/cm2 ∑PFAS from surfaces via soaking (targeted analysis). Treatment with 20% BC was 2- to 8-fold more effective than tap water at 70 °C and 10- to 20-fold more effective than tap water at 20 °C. Total fluorine analysis determined by combustion ion chromatography showed a 2- to 8-fold higher F-equivalent compared to targeted analysis in the cleaning solution after treatment, indicating the presence of a significant amount of polyfluoroalkyl PFAS. Surface analysis with ToF-ERD confirmed partial F removal from pipe surfaces throughout consecutive soaking intervals, with residual F remaining on pipe surfaces after treatment, leaving the risk of PFAS rebound into F-free firefighting foams. Furthermore, supramolecular assemblies of PFAS with at least 70 PFOS molecules/nm2 were identified by ToF-ERD on pipe interior surfaces.

sted, utgiver, år, opplag, sider
American Chemical Society (ACS), 2025. Vol. 59, nr 4, s. 2222-2232
Emneord [en]
AFFF, Per- and polyfluoroalkyl substances, butyl carbitol, desorption, foam transition, rebound effect, supramolecular assemblies, surfactant-surface interactions
HSV kategori
Identifikatorer
URN: urn:nbn:se:oru:diva-118846DOI: 10.1021/acs.est.4c09474ISI: 001403570500001PubMedID: 39846395Scopus ID: 2-s2.0-85216409705OAI: oai:DiVA.org:oru-118846DiVA, id: diva2:1931418
Forskningsfinansiär
EU, Horizon 2020, 860665EU, Horizon 2020, 824096Tilgjengelig fra: 2025-01-27 Laget: 2025-01-27 Sist oppdatert: 2026-01-23bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMedScopus

Person

Yeung, Leo W. Y.

Søk i DiVA

Av forfatter/redaktør
Yeung, Leo W. Y.
Av organisasjonen
I samme tidsskrift
Environmental Science and Technology

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 163 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf