To Örebro University

oru.seÖrebro universitets publikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Comparison of CIC and HR GFMAS for the measurements of extractable organofluorines (EOF) in different biological tissues of pilot whales
School of Biosciences, University of Aberdeen, UK; School of Natural and Computing Sciences, University of Aberdeen, UK; Department of Chemistry, Al-Qunfudhah University College, Umm Al-Qura University, Makkah, Saudi Arabia.
Örebro universitet, Institutionen för naturvetenskap och teknik. (Man-Technology-Environment (MTM) Research Centre)ORCID-id: 0000-0002-5360-2326
Department of Chemistry, College of Science, University of Jeddah, Jeddah, Saudi Arabia.
James Hutton Institute, Craigiebuckler, Aberdeen, UK; TESLA- Analytical Chemistry, University of Graz, Unversitätsplatz 1, 8010, Graz, Austria.
Vise andre og tillknytning
2025 (engelsk)Inngår i: Analytica Chimica Acta, ISSN 0003-2670, E-ISSN 1873-4324, Vol. 1351, artikkel-id 343855Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

BACKGROUND: In most water and biological samples, the sum of target or even non-target PFAS makes up only a small fraction of the extractable organofluorine (EOF). The methods used for EOF analysis in the methanol are combustion ion chromatography (CIC) and recently high-resolution graphite furnace molecular absorption spectrometry (HR GFMAS). Water samples show a bias towards higher concentrations measured with HR GFMAS than that of CIC. Whether the bias depends on the type of PFAS or on the sample matrix has not been known. Here we study the PFAS compound and the matrix effect using HR GFMAS and compare these with the CIC results.

RESULTS: Calibration of the HR GFMAS with fluoride exhibit significant higher response than using PFOA indicating a compound specific effect. PFOA calibration gave in the average quantitative recoveries for different type of PFAS in methanol, although neutral PFAS (FTOH) show lower recoveries than PFCA using HR GFMAS. Spiked PFOA in brain and liver tissue samples resulted in quantitative recoveries (101 %) using HR GFMAS. 44 liver, kidney, blubber and brain samples from stranded pilot whales were analysed by HR GFMAS and compared to the EOF concentrations analysed by CIC. All EOF results were above the LOD of both methods; 27 and 916 ng/g (CIC) and between 77 and 3130 ng/g (HR GFMAS). In general HR GFMAS gave significantly higher results for all tissues than CIC (p > 0.05). Correlations between the EOF of all tissues showed a tissue dependant behaviour.

SIGNIFICANCE: Since PFOA recovery was in brain and liver quantitative, the results indicate that PFAS type influence the performance using HR GFMAS. Overall, we found the concentrations in the different tissues to be comparable with the two methods within one order of magnitude. This highlights the fact that more work is needed to identify the matrix effects and fluorine species dependant responses of both methods.

sted, utgiver, år, opplag, sider
Elsevier, 2025. Vol. 1351, artikkel-id 343855
HSV kategori
Identifikatorer
URN: urn:nbn:se:oru:diva-120425DOI: 10.1016/j.aca.2025.343855ISI: 001486987400001PubMedID: 40187887Scopus ID: 2-s2.0-86000148744OAI: oai:DiVA.org:oru-120425DiVA, id: diva2:1950240
Merknad

Funding Agencies:

AAZ and AA thank the Cultural Bureau of Saudi Arabia and VM thanks the Macaulay Development Trust for the financial support. 

Tilgjengelig fra: 2025-04-07 Laget: 2025-04-07 Sist oppdatert: 2025-05-22bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMedScopus

Person

Aro, RudolfYeung, Leo W. Y.

Søk i DiVA

Av forfatter/redaktør
Aro, RudolfYeung, Leo W. Y.
Av organisasjonen
I samme tidsskrift
Analytica Chimica Acta

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 128 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf