Only fair accuracy of the radiographic classification of adult proximal humeral fractures in the Swedish Fracture Register: a cohort analysis
Division of Orthopaedic Surgery, Department of Biomedical and Clinical Sciences, Linköping University, Linköping, Sweden.
Division of Orthopaedic Surgery, Department of Biomedical and Clinical Sciences, Linköping University, Linköping, Sweden; Department of Orthopeadic Surgery, Ryhov County Hospital, Jönköping, Sweden.
Örebro universitet, Institutionen för medicinska vetenskaper. Region Örebro län. Division of Orthopaedic Surgery, Department of Biomedical and Clinical Sciences, Linköping University, Linköping, Sweden; Division of Orthopaedic Surgery, Örebro University, Örebro, Sweden.ORCID-id: 0000-0001-7873-3093
Division of Orthopaedic Surgery, Department of Biomedical and Clinical Sciences, Linköping University, Linköping, Sweden.
Vise andre og tillknytning
2025 (engelsk)Inngår i: Injury, ISSN 0020-1383, E-ISSN 1879-0267, Vol. 56, nr 8, artikkel-id 112558Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

INTRODUCTION: Quality registers are used for quality assessment, cost analyses, and research regarding outcomes of surgical and non-operative treatments. As the Swedish Fracture Register (SFR) expands, and is used as a platform for randomized trials, assuring reliability and accuracy of the data is essential. AIM: This study aimed to investigate the accuracy of the radiographic classification data for proximal humerus fractures recorded in the SFR.

METHOD: All radiographic images of 171 patients with a proximal humerus fracture registered in the SFR between 2019 and 03-01 and 2019-08-31 at 3 hospitals were included. The radiographs were independently assessed at 2 occasions >3 weeks apart by 1 surgeon at each center and IRR was calculated to validate the modification of the AO/OTA classification used in the register. A "gold standard" classification for each patients' images was then established with a consensus discussion involving 4 shoulder surgeons. The gold standard classification was compared with the classification registered in the SFR.

RESULTS: Intra-rater reliability was moderate (kappa 0.549-0.596) with percent agreement (PA) 61-66 %. Inter-rater reliability was also moderate (kappa 0.508-0.557) with PA 58-62 %. Accuracy of the SFR recordings compared with gold standard was fair with kappa 0.36 (95 % CI 0.297-0.425) and PA 44 %.

CONCLUSION: For registers to be of use the accuracy of data is essential as well as coverage, completeness, validity and reliability. The modified AO/OTA classification for proximal humerus fractures used in the SFR had moderate reliability but registered data only fair accuracy compared with a gold standard. This questions its value as a base for scientific research and clinical decisions.

sted, utgiver, år, opplag, sider
Elsevier, 2025. Vol. 56, nr 8, artikkel-id 112558
Emneord [en]
Accuracy, Classification, Proximal humeral fracture, Register, Trauma
HSV kategori
Identifikatorer
URN: urn:nbn:se:oru:diva-122397DOI: 10.1016/j.injury.2025.112558ISI: 001533832600001PubMedID: 40639131Scopus ID: 2-s2.0-105009879710OAI: oai:DiVA.org:oru-122397DiVA, id: diva2:1983528
Forskningsfinansiär
Medical Research Council of Southeast Sweden (FORSS), FORSS-981792Region Östergötland, 30522028Linköpings universitetTilgjengelig fra: 2025-07-11 Laget: 2025-07-11 Sist oppdatert: 2026-01-23bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMedScopus

Person

Adolfsson, Lars

Søk i DiVA

Av forfatter/redaktør
Adolfsson, Lars
Av organisasjonen
I samme tidsskrift
Injury

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 33 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf