Impact of iterative reconstruction on image quality of low-dose CT of the lumbar spine
Örebro universitet, Institutionen för medicinska vetenskaper. Region Örebro län. Department of Radiology, Örebro University Hospital, Örebro, Sweden.ORCID-id: 0000-0003-0137-9991
Örebro universitet, Institutionen för medicinska vetenskaper. Region Örebro län. Department of Radiology, Örebro University Hospital, Örebro, Sweden; Department of Medical Imaging and Physiology, Skåne University Hospital, Lund University, Lund, Sweden.ORCID-id: 0000-0003-0529-7723
Örebro universitet, Institutionen för medicinska vetenskaper. Region Örebro län. Department of Medical Physics, Örebro University Hospital, Örebro, Sweden.
Örebro universitet, Institutionen för medicinska vetenskaper. Region Örebro län. Department of Radiology, Örebro University Hospital, Örebro, Sweden.ORCID-id: 0000-0002-1346-1450
Visa övriga samt affilieringar
2017 (Engelska)Ingår i: Acta Radiologica, ISSN 0284-1851, E-ISSN 1600-0455, Vol. 58, nr 6, s. 702-709Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Background: Iterative reconstruction (IR) is a recent reconstruction algorithm for computed tomography (CT) that can be used instead of the standard algorithm, filtered back projection (FBP), to reduce radiation dose and/or improve image quality.

Purpose: To evaluate and compare the image quality of low-dose CT of the lumbar spine reconstructed with IR to conventional FBP, without further reduction of radiation dose.

Material and Methods: Low-dose CT on 55 patients was performed on a Siemens scanner using 120 kV tube voltage, 30 reference mAs, and automatic dose modulation. From raw CT data, lumbar spine CT images were reconstructed with a medium filter (B41f) using FBP and four levels of IR (levels 2-5). Five reviewers scored all images on seven image quality criteria according to the European guidelines on quality criteria for CT, using a five-grade scale. A side-by-side comparison was also performed.

Results: There was significant improvement in image quality for IR (levels 2-4) compared to FBP. According to visual grading regression, odds ratios of all criteria with 95% confidence intervals for IR2, IR3, IR4, and IR5 were: 1.59 (1.39-1.83), 1.74 (1.51-1.99), 1.68 (1.46-1.93), and 1.08 (0.94-1.23), respectively. In the side-by-side comparison of all reconstructions, images with IR (levels 2-4) received the highest scores. The mean overall CTDIvol was 1.70 mGy (SD 0.46; range, 1.01-3.83 mGy). Image noise decreased in a linear fashion with increased strength of IR.

Conclusion: Iterative reconstruction at levels 2, 3, and 4 improves image quality of low-dose CT of the lumbar spine compared to FPB.

Ort, förlag, år, upplaga, sidor
London: Sage Publications, 2017. Vol. 58, nr 6, s. 702-709
Nyckelord [en]
X-ray computed tomography (CT), image manipulation/reconstruction, lumbar vertebrae, radiation dosage, spine
Nationell ämneskategori
Radiologi och bildbehandling
Identifikatorer
URN: urn:nbn:se:oru:diva-57646DOI: 10.1177/0284185116669870ISI: 000399995700011PubMedID: 28157395Scopus ID: 2-s2.0-85019010032OAI: oai:DiVA.org:oru-57646DiVA, id: diva2:1095142
Tillgänglig från: 2017-05-12 Skapad: 2017-05-12 Senast uppdaterad: 2024-03-06Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Alshamari, MuhammedGeijer, MatsNorrman, EvaLidén, MatsKrauss, WolfgangJendeberg, JohanGeijer, Håkan

Sök vidare i DiVA

Av författaren/redaktören
Alshamari, MuhammedGeijer, MatsNorrman, EvaLidén, MatsKrauss, WolfgangJendeberg, JohanGeijer, Håkan
Av organisationen
Institutionen för medicinska vetenskaperRegion Örebro län
I samma tidskrift
Acta Radiologica
Radiologi och bildbehandling

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 735 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf