Till Örebro universitet

oru.seÖrebro universitets publikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
A method for analysis of marker persistent organic pollutants in low-volume plasma and serum samples using 96-well plate solid phase extraction
Örebro universitet, Institutionen för naturvetenskap och teknik. (MTM)
RECETOX, Masaryk University, Brno, Czech Republic.
Örebro universitet, Institutionen för naturvetenskap och teknik. Department of Medical Sciences, Molecular Epidemiology and Science for Life Laboratory, Uppsala University, Uppsala, Sweden. (MTM)ORCID-id: 0000-0001-5752-4196
Department of Medical Sciences, Occupational and Environmental Medicine, Uppsala University, Uppsala, Sweden.
Visa övriga samt affilieringar
2018 (Engelska)Ingår i: Journal of Chromatography A, ISSN 0021-9673, E-ISSN 1873-3778, Vol. 1546, s. 18-27Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

The objective of this study was to develop and validate a 96-well plate solid phase extraction method for analysis of 23 lipophilic persistent organic pollutants (POPs) in low-volume plasma and serum samples which is applicable for biomonitoring and epidemiological studies. The analysis of selected markers for internal exposure: 16 polychlorinated biphenyls (PCBs), 5 organochlorine pesticides (OCPs), octachlorinated dibenzo-p-dioxin (OCDD), and polybrominated diphenylether 47 (BDE 47) was evaluated by comparing two SPE sorbents and GC-HRMS or GC-MS/MS detection. The final method extracted 23 POPs from 150 μL of serum and plasma using a 96-well extraction plate containing 60 mg Oasis HLB sorbent per well prior to GC-HRMS magnetic sector analysis. The extraction method was applied to 40 plasma samples collected for an epidemiological study. The recovery of selected POPs ranged from 31% to 63% (n = 48), and detection limits ranged from 2.2 to 45 pg/mL for PCBs, 4.2 to 167 pg/mL for OCPs, 7.8 pg/mL for OCDD and 6.1 pg/mL for BDE 47. This method showed good precision with relative standard deviations of selected POP concentrations in quality control samples (n = 48) ranging from 11% to 25%. The trueness was determined with standard reference material serum (n = 48) and the deviation from certified values ranged from 1 to 27%. Of the 23 POPs analyzed, 18 were detected in 43% to 100% of plasma samples collected for the epidemiological study. The method showed good robustness with low inter-well plate variation (11-31%) determined by twelve 96-well plate extractions, and can extract 96 samples, including quality controls and procedural blanks in 2-3 days. Comparison with GC-MS/MS analysis showed that similar concentrations (within 0.5% to 30%) of most POPs could be obtained with GC-APCI-MS/MS. Larger deviations were observed for PCB 194 (60%) and trans-nonachlor (43%). The developed method produces accurate concentrations of low-level marker POPs in plasma and serum, providing a suitable high-throughput sample preparation procedure for biomonitoring and epidemiological studies involving large sample size and limited sample volume. GC-HRMS was chosen over GC-MS/MS, however the latter showed promising results, and could be used as an alternative to GC-HRMS analysis for most POPs.

Ort, förlag, år, upplaga, sidor
Elsevier, 2018. Vol. 1546, s. 18-27
Nyckelord [en]
High-throughput SPE, Persistent organic pollutants, GC-HRMS, APCI-MS/MS
Nationell ämneskategori
Analytisk kemi
Identifikatorer
URN: urn:nbn:se:oru:diva-66713DOI: 10.1016/j.chroma.2018.02.057ISI: 000430766800003PubMedID: 29510870Scopus ID: 2-s2.0-85042642069OAI: oai:DiVA.org:oru-66713DiVA, id: diva2:1200218
Forskningsfinansiär
Forskningsrådet Formas, 216-2013-478
Anmärkning

Funding Agency:

RECETOX Research Infrastructure  LM2015051  CZ.02.1.01/0.0/0.0/16_013/0001761

Tillgänglig från: 2018-04-23 Skapad: 2018-04-23 Senast uppdaterad: 2022-02-03Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Stubleski, JordanSalihovic, SamiraKärrman, Anna

Sök vidare i DiVA

Av författaren/redaktören
Stubleski, JordanSalihovic, SamiraKärrman, Anna
Av organisationen
Institutionen för naturvetenskap och teknik
I samma tidskrift
Journal of Chromatography A
Analytisk kemi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 2710 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf