Till Örebro universitet

oru.seÖrebro universitets publikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
B-spline based free form deformation thoracic non-rigid registration of CT and PET images
Tehran University of Medical Science, Tehran, Islamic Republic of Iran.ORCID-id: 0000-0003-2960-3094
Tehran University of Medical Science, Tehran, Islamic Republic of Iran.
Tehran University of Medical Science, Tehran, Islamic Republic of Iran.
Tehran University of Medical Science, Tehran, Islamic Republic of Iran.
Visa övriga samt affilieringar
2011 (Engelska)Ingår i: International Conference on Graphic and Image Processing (ICGIP 2011) / [ed] Yi Xie & Yanjun Zheng, SPIE - International Society for Optical Engineering, 2011, Vol. 8285, artikel-id 82851KKonferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

Accurate attenuation correction of emission data is mandatory for quantitative analysis of PET images. One of the main concerns in CT-based attenuation correction(CTAC) of PET data in multimodality PET/CT imaging is misalignment between PET and CT images. The aim of this study, is to proposed a hybrid method which is simple, fast and accurate, for registration of PET and CT data which affected from respiratory motion in order to improve the quality of CTAC. The algorithm is composed of three methods: First, using B-spline Free Form Deformation to describe both images and deformation field. Then applying a pre-filtering on both PET and CT images before segmentation of structures in order to reduce the respiratory related attenuation correction artifacts of PET emission data. In this approach, B-spline using FFD provide more accurate adaptive transformation to align the images, and structure constraints obtained from prefiltering applied to guide the algorithm to be more fast and accurate. Also it helps to reduce the radiation dose in PET/CT by avoiding repetition of CT imaging. These advances increase the potential of the method for routine clinical application.

Ort, förlag, år, upplaga, sidor
SPIE - International Society for Optical Engineering, 2011. Vol. 8285, artikel-id 82851K
Serie
Proceedings of SPIE, the International Society for Optical Engineering, ISSN 0277-786X, E-ISSN 1996-756X ; 8285
Nyckelord [en]
Positron Emission Tomography (PET), Computed Tomography (CT), Registration, thoracic, attenuation correction, B-spline, Free Form Deformation (FFD)
Nationell ämneskategori
Medicinsk bildvetenskap
Identifikatorer
URN: urn:nbn:se:oru:diva-72559DOI: 10.1117/12.913422ISI: 000295933400055Scopus ID: 2-s2.0-80054696621OAI: oai:DiVA.org:oru-72559DiVA, id: diva2:1289905
Konferens
International Conference on Graphic and Image Processing (ICGIP), Cairo, Egypt, October 1-2, 2011
Tillgänglig från: 2019-02-19 Skapad: 2019-02-19 Senast uppdaterad: 2025-02-09Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Khodadad, Davood

Sök vidare i DiVA

Av författaren/redaktören
Khodadad, Davood
Medicinsk bildvetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 221 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf