Till Örebro universitet

oru.seÖrebro universitets publikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Determination of reference values for optical properties of liquid phantoms based on Intralipid and India ink
Consiglio Nazionale delle Ricerche–Istituto di Fotonica e Nanotecnologie, Milano, Italy.
IBIB, Nalecz Instutute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Warsaw, Poland.
IBIB, Nalecz Instutute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Warsaw, Poland.
IBIB, Nalecz Instutute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Warsaw, Poland.
Visa övriga samt affilieringar
2014 (Engelska)Ingår i: Biomedical Optics Express, E-ISSN 2156-7085, Vol. 5, nr 7, s. 2037-2053Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

A multi-center study has been set up to accurately characterize the optical properties of diffusive liquid phantoms based on Intralipid and India ink at near-infrared (NIR) wavelengths. Nine research laboratories from six countries adopting different measurement techniques, instrumental set-ups, and data analysis methods determined at their best the optical properties and relative uncertainties of diffusive dilutions prepared with common samples of the two compounds. By exploiting a suitable statistical model, comprehensive reference values at three NIR wavelengths for the intrinsic absorption coefficient of India ink and the intrinsic reduced scattering coefficient of Intralipid-20% were determined with an uncertainty of about 2% or better, depending on the wavelength considered, and 1%, respectively. Even if in this study we focused on particular batches of India ink and Intralipid, the reference values determined here represent a solid and useful starting point for preparing diffusive liquid phantoms with accurately defined optical properties. Furthermore, due to the ready availability, low cost, long-term stability and batch-to-batch reproducibility of these compounds, they provide a unique fundamental tool for the calibration and performance assessment of diffuse optical spectroscopy instrumentation intended to be used in laboratory or clinical environment. Finally, the collaborative work presented here demonstrates that the accuracy level attained in this work for optical properties of diffusive phantoms is reliable.

Ort, förlag, år, upplaga, sidor
Optical Society of America, 2014. Vol. 5, nr 7, s. 2037-2053
Nyckelord [en]
Medical optics instrumentation, Photon migration, Turbid media, Absorption coefficient, Attenuation coefficient, Diffuse optical spectroscopy, Graded index fibers, Light propagation, Optical properties
Nationell ämneskategori
Sannolikhetsteori och statistik
Identifikatorer
URN: urn:nbn:se:oru:diva-76723DOI: 10.1364/BOE.5.002037ISI: 000338929100005OAI: oai:DiVA.org:oru-76723DiVA, id: diva2:1354196
Tillgänglig från: 2019-09-24 Skapad: 2019-09-24 Senast uppdaterad: 2023-02-17Bibliografiskt granskad

Open Access i DiVA

Determination of reference values for optical properties of liquid phantoms based on Intralipid and India ink(1015 kB)127 nedladdningar
Filinformation
Filnamn DATASET01.pdfFilstorlek 1015 kBChecksumma SHA-512
7fd489f77eb5745bc804dd04acd2a1addbe67750645ecbeb9e017a641870226da00b9183dfca27dc3def53b417055074ad280994575d88e117b9d5aece853c2e
Typ datasetMimetyp application/pdf

Övriga länkar

Förlagets fulltext

Person

Bodnar, Olha

Sök vidare i DiVA

Av författaren/redaktören
Bodnar, Olha
I samma tidskrift
Biomedical Optics Express
Sannolikhetsteori och statistik

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 0 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 170 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf