Till Örebro universitet

oru.seÖrebro universitets publikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Effects on Nasal Airflow and Resistance Using Two Different RME Appliances: A Randomized Controlled Trial
Örebro universitet, Institutionen för medicinska vetenskaper. Region Örebro län. Department of Orthodontics.ORCID-id: 0000-0002-9851-8996
Örebro University Hospital, Örebro, Sweden.
Private Orthodontic Office, Traben-Trarbach, Germany; University of Saarland, Homburg, Germany.
2018 (Engelska)Ingår i: European Journal of Orthodontics, ISSN 0141-5387, E-ISSN 1460-2210, Vol. 40, nr 3, s. 281-284Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Objectives: To evaluate and compare the effects of tooth-borne (TB) and tooth-bone-borne (TBB) rapid maxillary expansion (RME) on nasal airflow and resistance. Material and methods: Fifty-four consecutive patients who met the eligibility criteria were recruited from September 2010 to December 2015. Of these 54 subjects, 40 agreed to participate in the part of the study involving evaluation of nasal flow and resistance. The 40 subjects were allocated to either the TB group, mean age 9.7 years (SD 1.5), or the TBB group, mean age 10.2 years (SD 1.4). All subjects performed rhinomanometric registration at baseline (T-0), but only 30 attended the post-expansion registration (T-1), of whom 16 had been randomized to the TB group and 14 to the TBB group. The study outcomes, nasal airflow and nasal airway resistance, were evaluated with linear regression adjusted for baseline variable of the outcome to compare the study groups with complete cases strategy as well as after multiple imputation (MI). Randomization: Participants were randomly allocated in blocks of different sizes, using the concealed allocation principle in a 1:1 ratio. The randomization list was computer generated to ensure homogeneity between groups. Blinding: Blinding was done only for outcome assessor due to clinical limitations. The care providers at the ENT unit who conducted all the rhinomanometry examinations were blinded to which group the patients were allocated to. Results: Complete case analysis showed significantly higher post-expansion nasal airflow values for the TBB group compared with the TB group, mean difference 51.0 cm(3)/s (P = 0.018). The evaluation after MI showed a similar significant mean difference, 52.7 cm(3)/s (P = 0.020) in favour of the TBB group when taking into account the missing values from the T-1 examination. Even reduction in nasal airway resistance showed similar pattern in favour of the TBB group. Limitations: Our results represent the short-term effects. A longer follow-up period would have been preferable. Conclusions: The TBB RME induced significantly higher nasal airway flow and lower nasal resistance values than TB RME. It might be wiser to use TBB RME in cases with constricted maxilla and upper airway obstruction.

Ort, förlag, år, upplaga, sidor
Oxford University Press, 2018. Vol. 40, nr 3, s. 281-284
Nationell ämneskategori
Annan medicin och hälsovetenskap
Identifikatorer
URN: urn:nbn:se:oru:diva-83546DOI: 10.1093/ejo/cjx081ISI: 000434154900008PubMedID: 29069383Scopus ID: 2-s2.0-85047743169OAI: oai:DiVA.org:oru-83546DiVA, id: diva2:1446517
Anmärkning

Funding Agency:

Uppsala-Orebro Regional Research Council, Sweden, Grant Number: RFR-72021

Tillgänglig från: 2020-06-24 Skapad: 2020-06-24 Senast uppdaterad: 2020-12-01Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Bazargani, Farhan

Sök vidare i DiVA

Av författaren/redaktören
Bazargani, Farhan
Av organisationen
Institutionen för medicinska vetenskaperRegion Örebro län
I samma tidskrift
European Journal of Orthodontics
Annan medicin och hälsovetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 302 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf